This converter uses a nonsinusoidal waveform. Therefore, we do not recommend you use it to power the following devices:

1.Switch mode power supplies

2.Linear power supplies

3.Class 2 transformers

4.Line filter capacitors

5.Shaded pole motors

6.Fan motors

7.Microwave ovens

8.Fluorescent and high intensity lamps (with a ballast)

9.Transformerless battery chargers

Doing so may cause the device to run warmer or overheat.

3.FASTENING THE CONVERTER TO A FLAT SURFACE

For convenience, your converter can be fastened to a flat surface, horizontally or vertically. The area where the converter is to be fastened must be dry, well ventilated and away from any combustible material or fumes.

1.Turn off and disconnect the converter.

2.Place the back of the converter with the mounting bracket against a secure and flat surface.

3.Attach the converter to the flat surface using corrosion- resistant screws.

4.CONNECTING CONVERTER CABLES

The converter and power source must be in the OFF mode.

Make sure you connect your converter to a 12V power supply only.

Converter connection:

1.Locate the positive and negative plastic terminals located on the back of the converter and remove the terminal caps completely.

2.Install the positive (red) cable ring lug onto the positive (red) terminal screw. Install the negative (black) cable ring lug onto the negative (black) terminal screw. Tighten each terminal, so that the cable cannot come loose.

• 5 •

Page 5
Image 5
Schumacher X141B owner manual Fastening the Converter to a Flat Surface, Connecting Converter Cables, Converter connection