148 Fibre Channel Interface Manual, Rev. DTable 90: Actual Retry Count bytes
Field definitions (listed alphabetically)
Actual Retry Count
Returns implementation-specific information on the actual number of retries used in attempting to recover an error or
exception condition.
Note. This field relates to the retry count fields specified within the Verify Error Recovery Page (07h) parameters of the
Mode Select command. See Table 151.
SKSV (Sense Key Specific Valid)
This bit indicates whether the sense key specific data is valid.
0 Data is not valid.
1 Data is valid. See Table 88.
Field definitions (listed alphabetically)
Progress Indication
Percent complete indication in which the returned value is the numerator that has 65536 (10000h) as its denominator. The
progress indication is based upon the total format operation including any certification or initialization operations.
Support or non-support for format progress indication is given in individual drive’s Product Manual, Volume 1.
Note. Bytes 18–n are not presently used.
SKSV (Sense Key Specific Valid)
This bit indicates whether the sense key specific data is valid.
0 Data is not valid.
1 Data is valid. See Table 88.
Bit
Byte
76543210
15 SKSV Reserved
16 (MSB) Actual Retry Count
17 (LSB)
Table 91: Format Indication bytes
Bit
Byte
76543210
15 SKSV Reserved
16 (MSB) Progress Indication
17 (LSB)
Table
number
90
90
Table
number
91