18 | Barracuda 36 Installation Guide, Rev. B |
[5]See “Conducted noise immunity” in the Barracuda 36 Prod- uct Manual. The specified voltage tolerance is inclusive of ripple, noise, and transient response.
[6]Operating condition is defined as random seek read opera- tions with a block count of 64.
General Notes from Table 2.
1.Minimum current loading for each supply voltage is not less than 4% of the maximum operating current shown.
2.Use separate ground returns for +5V and +12V supplies.
3.Where power is provided to multiple drives from a common supply, carefully consider individual drive power require- ments. Where multiple units are powered on simultaneously, be sure the peak starting current is available to each device.
Table 3 shows the nominal dimensions and weight of the drive.
Table 3. | Dimensions of the drive | |
|
|
|
| inches | mm |
|
|
|
|
|
|
Height | 1.62 | 41.1 |
|
|
|
Width | 4.00 | 101.6 |
|
|
|
Depth | 5.75 | 146.05 |
|
|
|
Weight | 2.2 pounds (0.99 kilograms) | |
|
|
|