18

Barracuda 36 Installation Guide, Rev. B

[5]See “Conducted noise immunity” in the Barracuda 36 Prod- uct Manual. The specified voltage tolerance is inclusive of ripple, noise, and transient response.

[6]Operating condition is defined as random seek read opera- tions with a block count of 64.

General Notes from Table 2.

1.Minimum current loading for each supply voltage is not less than 4% of the maximum operating current shown.

2.Use separate ground returns for +5V and +12V supplies.

3.Where power is provided to multiple drives from a common supply, carefully consider individual drive power require- ments. Where multiple units are powered on simultaneously, be sure the peak starting current is available to each device.

Table 3 shows the nominal dimensions and weight of the drive.

Table 3.

Dimensions of the drive

 

 

 

 

inches

mm

 

 

 

 

 

 

Height

1.62

41.1

 

 

 

Width

4.00

101.6

 

 

 

Depth

5.75

146.05

 

 

 

Weight

2.2 pounds (0.99 kilograms)

 

 

 

Page 20
Image 20
Seagate ST136475LW/LC manual Dimensions of the drive