Barracuda 36 Installation Guide, Rev. B

17

Table 2. DC power requirements (Amps), multimode

 

 

 

(SE/LVD)

 

 

 

 

 

 

 

 

ST136475LW/LC

 

Voltage

+5V

+12V

 

Regulation [5]

±5%

±5%[2]

 

Max. operating current

 

 

 

DC [1]

1.4

1.5

 

Avg. idle current

 

 

 

 

 

[1]

 

 

0.75

0.8

 

DCX

 

 

 

Max. starting current

 

 

 

(peak DC) [3]

1.05

2.8

 

(peak AC) [3]

4.2

 

Delayed motor

 

 

 

start (max) [1][4]

0.65

0.030

 

Peak operating current

 

 

 

 

 

[1][6]

1.05

1.3

 

Typical DCX

 

Maximum DC [1]

1.4

1.5

 

Maximum (peak)

1.7

3.15

 

[1]Measured with an average reading DC ammeter. Instanta- neous +12V current peaks will exceed these values.

[2]A –10% droop is permissible during initial start of the spindle but must return to ±5% before reaching 7,200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See the +12V current profile in the Barracuda 36 Product Manual (publication number 77767528).

[4]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.

Page 19
Image 19
Seagate ST136475LW/LC manual DC power requirements Amps, multimode