Barracuda 4 Installation Guide, Rev. E

39

Other applicable jumper options

Several other jumper options are available as illustrated.

SCSI

Connector

DC Power

Connector

Reserved (RES)

Pin 1

J4

J4

RES MTR WP RES

PAR DMS LED

drivesN/ND

Reserved for future use.

Parity Check option (PAR)

Enable parity check of SCSI bus data (default).

Disable parity check.

Motor Start option (MTR)

Enable motor start. The drive waits for the Start Unit command from the host before starting the spindle motor.

Disable motor start (default). The drive starts according to the

Delay Motor Start option setting as described below.

Delay Motor Start option (DMS)

(valid only if the Motor Start jumper is not connected)

Motor start delay equal to the SCSI ID multiplied by 10 seconds.

For example, if the SCSI ID=2, the drive starts in 20 seconds.

Disable the delay motor start option (default).

Write Protect option (WP)

Write Protect = On (disables writing).

Write Protect = Off (enables writing – default).

Remote LED Connector*

Pin 5 (top pin) is negative (cathode), Pin 6 (bottom pin) is positive (anode).

*Note to subsystem designers: In Europe, a red LED indicates an error or warning condition. For this reason, you may want to use a color other than red with this connection.

Figure 14. Additional jumper options

Page 41
Image 41
Seagate ST15150N/ND/DC, ST15150W/WD/WC manual Several other jumper options are available as illustrated