Drive Specifications

www.seagate.com

2.10.1 Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-

7)to discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.

2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 4 Radio frequency environments

Test

Description

Performance

Reference

Level

standard

 

 

 

 

 

 

Electrostatic

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

discharge

 

 

 

 

 

 

 

 

 

 

80MHz to 1,000MHz, 3 V/m,

A

EN61000-4-3: 96

Radiated RF

80% AM with 1kHz sine

 

ENV 50204: 95

immunity

900MHz, 3 V/m, 50% pulse modulation @

 

 

 

200Hz

 

 

 

 

 

 

Electrical fast

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN61000-4-4: 95

transient

 

 

 

 

 

 

 

 

 

Surge

± 1 kV differential, ± 2 kV common, AC mains

B

EN61000-4-5: 95

immunity

 

 

 

 

 

 

 

 

 

Conducted RF

150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz

A

EN61000-4-6: 97

immunity

sine

 

 

 

 

 

 

 

0% open, 5 seconds

C

EN61000-4-11: 94

Voltage dips,

0% short, 5 seconds

C

 

interrupts

40%, 0.10 seconds

C

 

 

70%, 0.01 seconds

B

 

 

 

 

 

2.12 Reliability

2.12.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)

The product shall achieve an Annualized Failure Rate (AFR) of 0.34% (MTBF of 0.75 million hours) when operated in an environment of ambient air temperatures of 25°C. Operation at temperatures outside the specifications in Section 2.9 may increase the product AFR (decrease MTBF). AFR and MTBF are population statistics that are not relevant to individual units.

AFR and MTBF specifications are based on the following assumptions for desktop personal computer environments:

2400 power-on-hours per year.

10,000 average motor start/stop cycles per year.

Operations at nominal voltages.

Temperatures outside the specifications in Section 2.9 may reduce the product reliability.

Normal I/O duty cycle for desktop personal computers. Operation at excessive I/O duty cycle may degrade product reliability.

20

Barracuda Green SATA Product Manual, Rev. D

Page 20
Image 20
Seagate ST2000DL003, ST1500DL003 manual Test for Prominent Discrete Tones PDTs, Electromagnetic immunity, Standard