6.4.4.2Vibration
a.
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
Vibration may be applied in the X, Y, or Z axis.
Operating normal translational random flat profile
0.4 gRMS |
b.
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
1.2 gRMS |
c.
The limits of
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding
Amplitudes above 1.0 G in the frequency range of
Vibration may be applied in the X, Y, or Z axis.
1.2 gRMS |
6.4.5Acoustics
Sound power during idle mode shall be 3.5 bels typical when measured to ISO 7779 specification. Sound power while operating shall be 3.7 bels typical when measured to ISO 7779 specification.
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea- sured according to Seagate specification
6.4.6Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
6.4.7Corrosive environment
Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment.
Cheetah 15K.6 SAS Product Manual, Rev. A | 35 |