Seagate ST3146756FC (FDE) Start/stop time, Format command execution time minutes, 176 144 100

Models: ST3450056FC (FDE) ST3146756FC (FDE) ST3300056FC (FDE)

1 94
Download 94 pages 38.22 Kb
Page 18
Image 18

4.2.2Format command execution time (minutes)

When changing sector sizes, the format times shown below may need to be increased by 30 minutes.

 

ST3450856FC

ST3300656FC

ST3146356FC

 

ST3450056FC

ST3300056FC

ST3146756FC

Maximum (with verify)

176

144

100

Maximum (without verify)

88

72

50

Note. There is no significant difference in the format time between FDE and non-FDE models of the same

 

capacity.

 

4.2.3

General performance characteristics

 

Sustainable disc transfer rate*:

 

Minimum

112 Mbytes/sec (typical)

Maximum

171 Mbytes/sec (typical)

Fibre Channel Interface maximum instantaneous transfer rate

400 Mbytes/sec* per port

Logical block sizes

 

Default is 512-byte data blocks

 

Sector sizes variable to 512, 520, 524 and 528 bytes.

 

Read/write consecutive sectors on a track

Yes

Flaw reallocation performance impact (for flaws reallocated at format time

Negligible

using the spare sectors per sparing zone reallocation scheme.)

 

Average rotational latency

2.0 msec

*Assumes no errors and no relocated logical blocks.

Rate measured from the start of the first logical block transfer to or from the host. 1MB/sec = 1,000,000 bytes/sec

4.3Start/stop time

If the Motor Start option is disabled, the drive becomes ready within 20 seconds after DC power is applied. If a recoverable error condition is detected during the start sequence, the drive executes a recovery procedure and the time to become ready may exceed 20 seconds. During spin up to ready time, the drive responds to some commands over the FC interface in less than 3 seconds after application of power. Stop time is 30 seconds (maximum) from removal of DC power.

If the Motor Start option is enabled, the internal controller accepts the commands listed in the Fibre Channel Interface Manual less than 3 seconds after DC power has been applied. After the Motor Start command has been received, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure). The Motor Start command can also be used to command the drive to stop the spindle.

There is no power control switch on the drive.

12

Cheetah 15K.6 FC Product Manual, Rev. C

Page 18
Image 18
Seagate ST3146756FC (FDE) Start/stop time, Format command execution time minutes, 176 144 100, Maximum without verify