Seagate ST373455FC, ST3146855FC, ST3300655FC manual Environmental limits, Temperature

Models: ST3146855FC ST373455FC ST3300655FC

1 96
Download 96 pages 46.03 Kb
Page 41
Image 41

ST373455FC

Typical power dissipation under idle conditions in 4 Gbit operation is 9.12 watts (31.1 BTUs per hour).

To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 7). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.

 

 

 

ST373455FC CURRENT/POWER vs THROUGHPUT (FC - 4GB)

 

 

1.400

 

 

 

Random 8 Block Reads

 

14.00

 

 

 

 

 

 

 

 

 

5Volt A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 Volt A

 

1.200

 

 

 

 

 

 

 

12.00

Watts

 

1.000

 

 

 

 

 

 

 

10.00

Power (watts)

Amperes

0.800

 

 

 

 

 

 

 

8.00

0.600

 

 

 

 

 

 

 

6.00

 

 

 

 

 

 

 

 

 

 

0.400

 

 

 

 

 

 

 

4.00

 

 

0.200

 

 

 

 

 

 

 

2.00

 

 

0.000

 

 

 

 

 

 

 

0.00

 

 

0.0

50.0

100.0

150.0

200.0

250.0

300.0

350.0

400.0

 

 

 

 

 

I/Os per Second

 

 

 

 

Figure 9. ST373455FC DC current and power vs. input/output operations per second at 4 Gbit

6.4Environmental limits

Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maximum wet bulb temperature is 82°F (28°C).

6.4.1Temperature

a.Operating

The maximum allowable continuous or sustained HDA case temperature for the rated Annualized Failure Rate (AFR) is 122°F (50°C) The maximum allowable HDA case temperature is 60°C. Occasional excur- sions of HDA case temperatures above 122°F (50°C) or below 41°F (5°C) may occur without impact to the specified AFR. Continual or sustained operation at HDA case temperatures outside these limits may degrade AFR.

Provided the HDA case temperatures limits are met, the drive meets all specifications over a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 36°F (20°C) per hour. Air flow may be needed in the drive enclosure to keep within this range (see Section 8.3). Operation at HDA case temperatures outside this range may adversely affect the drives ability to meet specifications. To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized.

Cheetah 15K.5 FC Product Manual, Rev. D

31

Page 41
Image 41
Seagate ST3146855FC, ST3300655FC manual Environmental limits, Temperature, ST373455FC CURRENT/POWER vs Throughput FC 4GB