www.seagate.com

Drive Specifications

2.8.1 Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-

7)to discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.

2.9Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5 Radio frequency environments

Test

Description

Performance level

Reference

standard

 

 

 

 

Electrostatic

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

discharge

 

 

 

 

 

 

 

Radiated RF

80 to 1,000MHz, 3 V/m,

A

EN61000-4-3: 96

immunity

80% AM with 1kHz sine

 

ENV 50204: 95

 

900MHz, 3 V/m, 50% pulse modulation @

 

 

 

200Hz

 

 

 

 

 

 

Electrical fast

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN61000-4-4: 95

transient

 

 

 

 

 

 

 

Surge immu-

± 1 kV differential, ± 2 kV common, AC mains

B

EN61000-4-5: 95

nity

 

 

 

 

 

 

 

Conducted RF

150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz

A

EN61000-4-6: 97

immunity

sine

 

 

 

 

 

 

Voltage dips,

0% open, 5 seconds

C

EN61000-4-11: 94

interrupts

0% short, 5 seconds

C

 

 

40%, 0.10 seconds

C

 

 

70%, 0.01 seconds

B

 

 

 

 

 

Barracuda XT SATA Product Manual, Rev. D