Cheetah NS 10K.2 FC
ST3600002FC ST3450802FC ST3300602FC
Page
Contents
Installation
Seagate Technology support services
Cheetah NS 10K.2 FC Product Manual, Rev. B
Scope
Cheetah NS 10K.2 FC Product Manual, Rev. B
Standards, compliance and reference documents
Standards
Electromagnetic compatibility
Electromagnetic susceptibility
Compliance
Reference documents
Ncits TR-19
Cheetah NS 10K.2 FC Product Manual, Rev. B
General description
Standard features
Media description
Reliability
Performance
Formatted capacities
User-installed accessories
Factory-installed options
Programmable drive capacity
Performance characteristics
Internal drive characteristics
Access time
Seek performance
Format command execution time minutes
General performance characteristics
Start/stop time
ST3600002FC ST3450802FC ST3300602FC
Prefetch/multi-segmented cache control
Cache operation
Caching write data
Prefetch operation
Reliability specifications
Error rates
Recoverable Errors
Unrecoverable Errors
Reliability and service
Seek errors
Interface errors
Preventive maintenance
A.R.T. delay times
4 S.M.A.R.T
Controlling S.M.A.R.T
Performance impact
Reporting control
Determining rate
Predictive failures
Thermal monitor
State of the drive prior to testing
Temperature Log Page 0Dh
Drive Self Test DST
DST failure definition
Invoking DST
Short and extended tests
Short test Function Code 001b
Extended test Function Code 010b
Product warranty
Abort
Cheetah NS 10K.2 FC Product Manual, Rev. B
Physical/electrical specifications
AC power requirements
DC power requirements
DC power requirements for ST3600002FC model Gbit Amps
DC power requirements for ST3450802FC model Gbit Amps
General DC power requirement notes
DC power requirements for ST3300602FC model Gbit Amps
Conducted noise immunity
Power sequencing
Current profiles
Cheetah NS 10K.2 FC Product Manual, Rev. B
Cheetah NS 10K.2 FC Product Manual, Rev. B
Power dissipation
ST3600002FC
ST3450802FC
ST3300602FC
Environmental limits
Temperature a. Operating
Relative humidity
Shock and vibration
Effective altitude sea level a. Operating
Shock
Package size Packaged/product weight Drop height
Recommended mounting
Air cleanliness
Vibration a. Operating-normal
Acoustics
Corrosive environment
China Restriction of Hazardous Substances RoHS Directive
Mechanical specifications
Mounting configuration dimensions
Cheetah NS 10K.2 FC Product Manual, Rev. B
Drive internal defects/errors
Defect and error management
Drive error recovery procedures
77.81
Background Media Scan
FC-AL system errors
Media Pre-Scan
Deferred Auto-Reallocation
Idle Read After Write
Installation
Drive ID/option selection
Drive orientation
Cooling
Drive mounting
Air flow
Grounding
Cheetah NS 10K.2 FC Product Manual, Rev. B
FC-AL features
Fibre Channel link service frames
Link services supported Type of frame
Interface requirements
Fibre Channel task management responses
Fibre Channel task management functions
FC Scsi FCP response codes Function name Response code
Fibre Channel port login
NPort login Plogi payload Bytes
Fibre Channel port login accept
Fibre Channel Process Login
NPort Login Accept ACC payload Bytes
Process Login Plri payload
Fibre Channel Process Login Accept
Fibre Channel fabric login
Process Login Accept ACC payload Bytes
Fabric Login Flogi payload Bytes
Fibre Channel fabric accept login
Fabric Login Accept ACC payload Bytes
Dual port support
Fibre Channel Arbitrated Loop options
FC-AL options supported
Option Supported
Scsi commands supported
Supported commands Command code Command name
Verify error recovery page 07h
Cheetah NS 10K.2 FC Product Manual, Rev. B
Temperature page 0Dh
Inquiry data
Mode Sense data
Cheetah NS 10K.2 FC inquiry data Bytes Data hex
Page
Mode Data Header
Mode Pages
00 00 05 12 8B 00 50
Miscellaneous operating features and conditions
Supported Feature or condition
FC-AL physical interface
Physical characteristics
Physical description
Electrical description
Connector requirements
Pin descriptions
FC-SCA pin descriptions Pin Signal name Signal type
FC-AL transmitters and receivers
Power
Fault LED Out
Active LED Out
Enable port bypass signals
Motor start controls
Parallel Enclosure Services Interface ESI
11 SEL6 through SEL0 ID lines
Alpa SEL ID
TTL input characteristics
Signal characteristics
Device control codes
FC Differential output
LED driver signals
FC Differential input
Receive eye diagram Eye diagram data values Link rate GHz
Cheetah NS 10K.2 FC Product Manual, Rev. B
Presales Support
Seagate Technology support services
Technical Support
Data Recovery Services Authorized Service Centers
Warranty Service
Data Recovery Services Call Center Toll-free Direct dial
Index
FCP
Flogi
Plogi
Page
See also cooling
Page
Seagate Technology LLC