ST3600002FC ST3450802FC ST3300602FC
Cheetah NS 10K.2 FC
Page
Contents
Installation
Seagate Technology support services
Cheetah NS 10K.2 FC Product Manual, Rev. B
Scope
Cheetah NS 10K.2 FC Product Manual, Rev. B
Electromagnetic susceptibility
Standards, compliance and reference documents
Standards
Electromagnetic compatibility
Compliance
Ncits TR-19
Reference documents
Cheetah NS 10K.2 FC Product Manual, Rev. B
General description
Media description
Standard features
Formatted capacities
Performance
Reliability
Programmable drive capacity
Factory-installed options
User-installed accessories
Seek performance
Performance characteristics
Internal drive characteristics
Access time
ST3600002FC ST3450802FC ST3300602FC
Format command execution time minutes
General performance characteristics
Start/stop time
Cache operation
Prefetch/multi-segmented cache control
Prefetch operation
Caching write data
Unrecoverable Errors
Reliability specifications
Error rates
Recoverable Errors
Preventive maintenance
Reliability and service
Seek errors
Interface errors
Performance impact
A.R.T. delay times
4 S.M.A.R.T
Controlling S.M.A.R.T
Thermal monitor
Reporting control
Determining rate
Predictive failures
DST failure definition
State of the drive prior to testing
Temperature Log Page 0Dh
Drive Self Test DST
Extended test Function Code 010b
Invoking DST
Short and extended tests
Short test Function Code 001b
Abort
Product warranty
Cheetah NS 10K.2 FC Product Manual, Rev. B
DC power requirements for ST3600002FC model Gbit Amps
Physical/electrical specifications
AC power requirements
DC power requirements
DC power requirements for ST3450802FC model Gbit Amps
DC power requirements for ST3300602FC model Gbit Amps
General DC power requirement notes
Current profiles
Power sequencing
Conducted noise immunity
Cheetah NS 10K.2 FC Product Manual, Rev. B
Cheetah NS 10K.2 FC Product Manual, Rev. B
ST3600002FC
Power dissipation
ST3450802FC
ST3300602FC
Relative humidity
Temperature a. Operating
Environmental limits
Shock
Effective altitude sea level a. Operating
Shock and vibration
Recommended mounting
Package size Packaged/product weight Drop height
Corrosive environment
Air cleanliness
Vibration a. Operating-normal
Acoustics
China Restriction of Hazardous Substances RoHS Directive
Mounting configuration dimensions
Mechanical specifications
Cheetah NS 10K.2 FC Product Manual, Rev. B
Drive error recovery procedures
Defect and error management
Drive internal defects/errors
77.81
Media Pre-Scan
FC-AL system errors
Background Media Scan
Idle Read After Write
Deferred Auto-Reallocation
Cooling
Installation
Drive ID/option selection
Drive orientation
Air flow
Drive mounting
Grounding
Cheetah NS 10K.2 FC Product Manual, Rev. B
Interface requirements
FC-AL features
Fibre Channel link service frames
Link services supported Type of frame
FC Scsi FCP response codes Function name Response code
Fibre Channel task management functions
Fibre Channel task management responses
NPort login Plogi payload Bytes
Fibre Channel port login
Process Login Plri payload
Fibre Channel port login accept
Fibre Channel Process Login
NPort Login Accept ACC payload Bytes
Fabric Login Flogi payload Bytes
Fibre Channel Process Login Accept
Fibre Channel fabric login
Process Login Accept ACC payload Bytes
Fabric Login Accept ACC payload Bytes
Fibre Channel fabric accept login
Option Supported
Dual port support
Fibre Channel Arbitrated Loop options
FC-AL options supported
Supported commands Command code Command name
Scsi commands supported
Verify error recovery page 07h
Cheetah NS 10K.2 FC Product Manual, Rev. B
Temperature page 0Dh
Cheetah NS 10K.2 FC inquiry data Bytes Data hex
Mode Sense data
Inquiry data
Page
Mode Data Header
Mode Pages
00 00 05 12 8B 00 50
Supported Feature or condition
Miscellaneous operating features and conditions
Physical description
Physical characteristics
FC-AL physical interface
Pin descriptions
Connector requirements
Electrical description
FC-AL transmitters and receivers
FC-SCA pin descriptions Pin Signal name Signal type
Fault LED Out
Power
Motor start controls
Enable port bypass signals
Active LED Out
11 SEL6 through SEL0 ID lines
Parallel Enclosure Services Interface ESI
Alpa SEL ID
Device control codes
Signal characteristics
TTL input characteristics
FC Differential input
LED driver signals
FC Differential output
Receive eye diagram Eye diagram data values Link rate GHz
Cheetah NS 10K.2 FC Product Manual, Rev. B
Technical Support
Seagate Technology support services
Presales Support
Data Recovery Services Call Center Toll-free Direct dial
Warranty Service
Data Recovery Services Authorized Service Centers
Index
FCP
Flogi
Plogi
Page
See also cooling
Page
Seagate Technology LLC