4.2.2Format command execution time (minutes)

 

ST3600002FC

ST3450802FC

ST3300602FC

Maximum (with verify)

182

129

83

Maximum (without verify)

101

68

43

Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to the Initiator (excluding connect/disconnect).

When changing sector sizes, the format times shown above may need to be increased by 30 minutes.

4.2.3

General performance characteristics

 

Sustainable disk transfer rate*:

 

Minimum

82 Mbytes/sec

Maximum

150 Mbytes/sec

Fibre Channel Interface maximum instantaneous transfer rate

800 Mbytes/sec* per port

 

 

(dual port = 1600 Mbytes/sec*)

Logical block sizes

 

Default is 512-byte data blocks

 

Sector sizes variable to 512, 520, 524 and 528 bytes.

 

Read/write consecutive sectors on a track

Yes

Flaw reallocation performance impact (for flaws reallocated at format time

Negligible

using the spare sectors per sparing zone reallocation scheme.)

 

*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.

4.3Start/stop time

The drive accepts the commands listed in the Fibre Channel Interface Manual less than 3 seconds after DC power has been applied.

If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.

The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 30 sec- onds (maximum) from removal of DC power.

There is no power control switch on the drive.

12

Cheetah NS 10K.2 FC Product Manual, Rev. B

Page 18
Image 18
Seagate ST3300602FC manual Start/stop time, Format command execution time minutes, General performance characteristics