Barracuda 5400.1 Product Manual, Rev. G | 17 |
2.12Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
|
| Performance | Reference |
Test | Description | level | standard |
|
|
|
|
|
|
|
|
Electrostatic | Contact, HCP, VCP: ± 4 kV; | B | EN |
discharge | Air: ± 8 kV |
|
|
|
|
|
|
Radiated RF | 80 to 1,000 MHz, 3 V/m, | A | EN |
immunity | 80% AM with 1 kHz sine |
| ENV 50204: 95 |
| 900 MHz, 3 V/m, 50% pulse |
|
|
| modulation @ 200 Hz |
|
|
|
|
|
|
Electrical fast | ± 1 kV on AC mains, ± 0.5 | B | EN |
transient | kV on external I/O |
|
|
|
|
|
|
Surge | ± 1 kV differential, ± 2 kV | B | EN |
immunity | common, AC mains |
|
|
|
|
|
|
Conducted | 150 kHz to 80 MHz, 3 Vrms, | A | EN |
RF immunity | 80% AM with 1 kHz sine |
|
|
|
|
|
|
Voltage dips, | 0% open, 5 seconds | C | EN |
interrupts | 0% short, 5 seconds | C |
|
| 40%, 0.10 seconds | C |
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
2.13 | Reliability |
|
Nonrecoverable read errors | 1 per 1014 bits read, max. | |
Mean time between failures | 600,000 | |
|
| (nominal power, 25°C ambient temperature) |
Service life |
| The drive shall have a useful service life of five years. |
Contact | 50,000 cycles. | |
|
| (at nominal voltage and temperature, with 60 cycles |
|
| per hour and a 50% duty cycle) |
Preventive maintenance | None required. |