9.1.7Fibre Channel Process Login Accept

Table 11 lists Savvio 10K.4 FC process login accept payload data.

Table 11:

Process Login Accept (ACC) payload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

02

10

00

14

08

00

 

21

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

00

00

00

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.1.8Fibre Channel fabric login

Table 12 lists the fabric login payload from the drive.

Table 12:

Fabric Login (FLOGI) payload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

04

00

00

00

09

09

00

00

08

00

08

40

00

00

00

00

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

00

00

02

F4

2P

00

CC

CC

CC

UI

UI

UI

02

00

CC

CC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-35

CC

UI

UI

UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36-47

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Class 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48-51

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-63

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-67

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-79

 

 

 

 

80

00

00

00

00

00

08

40

00

00

00

00

Class 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-83

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-95

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96-99

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-111

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Vendor -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-115

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).

UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields.

PPort identifier field.

1 FLOGI originated on Port A.

2 FLOGI originated on Port B.

46

Savvio 10K.4 FC Product Manual, Rev. A

Page 52
Image 52
Seagate ST900MM0036 Fibre Channel Process Login Accept, Fibre Channel fabric login, Process Login Accept ACC payload Bytes