[4]See +12V current profile in Figure 4.

[5]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.

[6]See paragraph 6.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.

[7]Operating condition is defined as random 8 block reads.

[8]During idle, the drive heads are relocated every 30 seconds to a random location within the band from three-quarters to maximum track

General DC power requirement notes.

1.Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current shown.

2.The +5V and +12V supplies should employ separate ground returns.

3.Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.

4.Parameters, other than spindle start, are measured after a 25-minute warm up.

5.No terminator power.

6.3.1Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.

+5

V

=

250 mV pp from 0 to

100 kHz to 20 MHz.

+12

V

=

800 mV pp from 100

Hz to 8 KHz.

 

 

 

450 mV pp from 8 KHz to 20 KHz.

 

 

 

250 mV pp from 20 KHz to 5 MHz.