SANITATION SYSTEM LAYOUT

SANITATION SYSTEM LAYOUT

SYSTEM GUIDELINES

1.Cassette vacuum tank must be used with VacuFlush toilet.

2.VacuFlush toilet must be connected to pressurized water supply (not shown).

3.Centerline of toilet base must be 11 inches (279 mm) from back wall.

4.5/8-inch (16mm) ID vent hose must be attached to vent fitting (not included).

INSTALLATION

DOCKING PLATFORM RISER

1. The riser section of the docking platform is

 

The riser and base sections

mounted on a level floor using four screws (not

 

must be assembled on the

supplied). The floor must be strong enough

ATTENTION

same level surface.

to support the weight of the cassette when full

 

(about 40 lbs. – 18 kg).

 

 

BACKFRONT

DOCKING PLATFORM BASE

1.The base section of the docking platform is at- tached to the riser. The base has two tabs (A) that must be pushed into the respective slots in the rear wall of the riser. Make sure that the connection (B) for the carbon filter fits into the space provided.

2.The ventilation hose (C) is routed out the side of the base. Using barbed hose adapter provided, route reinforced 5/8-inch (16mm) vent hose (not supplied) to an outside vent fitting.

3.Fasten the base of the docking platform to the surface (D).

Make sure that the carbon filter fits into the space provided (B) and is properly connected at both ends.

A

B

A

 

C

 

 

D