Checking Food Temperature

Checking Food Temperature

Twenty-four hours after the unit is installed, check the food temperature in the refrigerator and freezer sections. Use a quality thermometer that can reg- ister below zero temperatures

FREEZER: Place the thermometer in

the center of the freezer, surrounded by frozen packages Wait 5 to 8 hours, then check the reading. If temperature is not within 0° to +2 ° F,adjust control

as needed, one position at a time and check temperature again after 4 to

6 hours See Figure 21

REFRIGERATOR: Place the thermom- eter in a glass of water and place the glass in the middle of the refrigerator section° Be sure air can flow around it. Wait 3 to 4 hours, check the tempera- ture and adjust the control as needed

Power Miser Control

The 2-Position Power Miser Control lets you save energy by adjusting refrigera- tor operation to humidity level in your house. During hot, humid weather, any refrigeratodfreezer will form moisture around the doors, similar to the way condensate forms on a glass of ice water. The cabinet has special heaters to minimize this condensation. The Power Miser Control lets you turn these heaters higher or lower,

The upper position is for periods of

high humidity,

RefrigeratorFea±ures

Adjustable Cantilever Glass Shelves. These shelves attach to metal tracks in

the back of the interior. To remove, tap upwards at rear of shelf hooks Lift shelf and putl out. To install, tilt shelf and engage upper hooks in desired track slots. Lower shelf front and tap down- wards near the tracksuntil shelf hooks are securely seated and shelf is level.

one position at a time to achieve the 38 ° to 40 ° F range_Wait 3 to 4 hours and check the temperature again. See Rgure 22,

t;

-FROZEN FOOD PACKAGSS

FIGURE 21

GLA._S OF WATE_

FIGURE 22

The lower position is for maximum energy savings. Use for periods of low humidity. A minimum amount of con- densation is normal° During extreme high humidity, condensate may also form on the cabinet sides and doors This is normal -__

and will disap-

POWER MISER

pear when cli-

 

matic condi-

 

tions return to

REDUCES

MOISTURE

normal

 

SAVES

ENERGY

CAUTION:

To Avoid Personal Injury Or Prop- erty Damage test for proper instal- lation by exerting some pressure

downward on the frontedge,. Shelf should not move,

18

Page 18
Image 18
Sears 10062603 Checking Food Temperature, RefrigeratorFea±ures, Power Miser Control, The upper position is for periods of