Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

OPERATING YOUR WATER HEATER

Operating Instructions

Read and understand these directions thoroughly before attempting to operate the water heater. Make sure the view port is not missing or damaged (See Figure 36). Make sure the tank is completely filled with water before operating the water heater. The gas control valve/thermostat has a “On/Off Switch” and needs to be turned on before water heater is operational. Check the label on the front of heater near the gas control valve/ thermostat for the correct gas. Do not use this water heater with any gas other than the one listed on the label. If you have any questions or doubts, consult your gas supplier or gas utility company.

WARNING

Explosion Hazard

Replace view port if glass is missing or damaged.

Failure to do so can result in death, explosion or fire.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or

 

explosion may result causing property damage, personal injury

 

or loss of life.

FLAMMABLE

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance does not have a pilot. It is equipped with an ignition device that will automatically light the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your building.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in the electronic display buttons and gas control switch. Never use tools. If the control buttons will not push in, don't try to repair them, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit.

It must be replaced!

OPERATING INSTRUCTIONS

 

ON

FIGURE 28.

OFF

 

ON/OFF

 

SWITCH

 

"GAS CONTROL"

1.

STOP! Read the safety information

 

above on the label.

2.Turn on all electrical power to the appliance.

3.Set the ON/OFF switch on the gas control to the "ON" position.

4.Set the Electronic Display to the lowest setting by first pressing the COOLER and

HOTTER buttons together and holding for 1 second. Then press the COOLER button to the lowest setting.

5.Set the ON/OFF switch on the gas control to the "OFF" position.

6.This appliance is equipped with a device which automatically lights the burner.

DO NOT TRY TO LIGHT THE BURNER BY HAND.

7. Wait five (5) minutes to

clear out any gas.

If you then smell gas,

STOP! Follow "B" in

the safety information above on this label. If you don't smell gas, go to the next step.

"ELECTRONIC DISPLAY"

8.Set the ON/OFF switch on the gas control to the "ON" postition.

9.Set the Electronic Display to the desired setting by first

pressing the COOLER and HOTTER but- tons together and holding for 1 second. Then press

the HOTTER button until the desired setting is reached.

DANGER: Hotter water increases the risk scald injury. Consult the instruction manual before changing temperature.

10.If the appliance will not operate, follow the instruc- tions "TO TURN OFF GAS TO APPLIANCE" and call your technician or gas supplier.

WARNING: TURN OFF ALL ELECTRIC POWER BEFORE SERVICING.

TO TURN OFF GAS TO APPLIANCE

1.Set the Electronic Display to the lowest setting by first

pressing the COOLER and HOTTER but- tons together and holding for 1 second. Then press

the COOLER button to the lowest setting.

2.Set the ON/OFF switch on the gas control to the "OFF" postition.

3.Turn off all electrical power to the appliance if service is to be performed.

25

Page 25
Image 25
Sears 153.33262 manual Operating Your Water Heater, Operating Instructions

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.