continued:

PROBLEM

 

POSSIBLE CAUSE(S)

 

CORRECTIVE ACTION

 

1. Improperly sealed, hot or cold supply

1.

Tighten threaded connections.

 

 

connections, relief valve, drain valve or

 

 

WATER LEAKS

2.

thermostat threads.

2.

Inspect other appliances near water heater.

Leakage from other appliances or

 

3.

water lines.

3.

See “START UP CONDITIONS”, section.

 

Condensation of flue products.

 

4.

Excessive water pressure.

4.

Use a pressure reducing valve and relief valve.

 

5.

Heater stacking.

5.

Lower the thermostat setting.

 

6.

Closed water system.

6.

See “Closed System/Thermal Expansion”.

 

 

 

 

1. Thermal expansion in closed water

1. Install thermal expansion tank (DO NOT plug T&P

LEAKING T&P

 

system.

 

valve).

2.

Improperly seated valve.

2.

Check relief valve for proper operation (DO NOT

 

 

 

 

 

plug T&P valve.

 

 

 

 

 

1. High sulfate or mineral content in water

1.

Drain and flushing heater thoroughly then refill.

HOT WATER ODORS

 

supply.

 

 

2.

Bacteria in water supply.

2.

Chlorinate water supply.

 

 

 

 

 

 

1. Condensation dripping on burner.

1.

See “START UP CONDITIONS”, section.

WATER HEATER SOUNDS

2.

Sediment at bottom of heater tank.

2.

See “DRAINING AND FLUSHING”, section.

SIZZLING-RUMBLING

 

 

 

 

 

 

 

 

 

1.

Insufficient secondary air.

1. Provide ventilation to water heater. Check flue way,

SMOKING AND CARBON

 

 

 

flue baffle, burner.

2.

Low gas pressure.

2.

Check with gas utility company.

FORMATION (SOOTING)

3.

Water heater flue or vent system

3.

Clean, locate source and correct.

 

 

4.

blocked.

4.

Replace thermostat.

 

Thermostat not functioning properly.

 

5.

Heater installed in a confined area.

5.

Provide fresh air ventilation.

 

6.

Burner flame yellow-lazy.

6.

See “Burner Flame Yellow-Lazy”.

 

 

 

 

1. Thermostat set too high.

1. Set temperature to lower setting.

 

2.

Sediment or lime in tank.

2.

Drain/flush-provide water treatment if needed.

HIGH OPERATION COSTS

3.

Water heater too small for job.

3.

Install adequate heater.

4.

Wrong piping connections.

4.

Correct piping-dip tube must be in cold inlet.

 

5.

Leaking faucets.

5.

Repair faucets.

 

6.

Gas leaks.

6.

Check with utility-repair at once.

 

7.

Wasted hot water.

7.

Advise customer.

 

8.

Long runs of exposed piping.

8.

Insulate piping.

 

9.

Hot water piping in exposed wall.

9.

Insulate piping.

 

 

 

 

 

THERMOSTAT FAILS TO

1.

Thermostat not functioning properly.

1.

Replace thermostat.

SHUT-OFF

2.

Improper calibration.

2.

Replace thermostat.

 

 

 

 

 

1.

Excessive water pressure.

1. Use a pressure reducing valve and relief valve.

DRIP FROM RELIEF VALVE

2.

Heater stacking.

2.

Lower the thermostat setting.

 

3.

Closed water system.

3.

See “CLOSED SYSTEM/THERMAL EXPAN-

 

 

 

 

SION”, section.

 

 

 

 

 

37

Page 37
Image 37
Sears 153.33262 manual Sizzling-Rumbling

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.