[AWARNING[Hazardous fumes. Follow cement manu-
facturer's instructions. Use PVC cement only in a well ventilated place away from fire or flame.
11.Put clamp on adapter;, leave loose. Mount check valve in adapter; thread ag_nbly into tee.
12.Slip pump into check valve. Tighten clamp.
|
|
| ||
L__5JZ/Tee" PVC | / | |||
_/ | / | Pipe | ,r | Check |
|
| ValveC: ] |
[_-l,q_-- ReducerBushing(2 Supplied)
.@_-_- Main PumpDischargePipe
i*':_l'€-- Check Valve to Prevent
j, I RecirculationintoSump
I u I
L.... J
Figure 2B - Installation Diagram
13.Make sure battery is fully charged; then check operation
by disconnecting power to primary sump pump and fill- ing sump until Backup Sump Pump starts. Run Backup
Pump through one complete cycle.
ELECTRICAL CONNECTIONS
I AWARNINGIE[aZardous | voltage. | Can cause | serious | or | |||||
fatal | electrical | shock. | Review | safety | instructions, | Page | 2, | be- | |
fore | operating | charger. |
|
|
|
|
|
| |
If your outlet | is not | grounded, | install | a copper | wire (at | least |
14 gauge) | from | the outlet | box | to | a cold | water | pipe. | Use | |||
ground | clamp | on | pipe. BE | SURE | that | the | cold water | pipe | |||
used | has | metal |
| continuity | to | electrical | ground. | Battery | |||
charger | is | double | insulated. | DO | NOT | modify cord | or | plug. |
3. With charger properly connected and plugged in, the panel on the front of the charger will appear as in one of the following:
A. If battery is dead, charger will supply about 10 amps "power (see Figure 4A).
B. If battery is near full charge, charger will deliver about 5 amps power (see Figure 4B).
Black
Brown
Batten# Clamp
Positive
(Black Iv/
Red Tracer)
Black
1411 1104
Figure 3 - Wiring Connections
A.
CHARGER/BATTERY INSTALLATION
NOTICE: Alarm will sound when charger is first connected
to battery. Press ALARM TEST/RESET button on charger. If
alarm continues to sound, disconnect one charger lead from
1.Connect charger as shown in Figure 3.
A.Connect Positive (+) lead from charger to positive battery post.
B.Connect Negative
tery post. | " |
C. Third lead from c lMa'ger is factory connected to lead from
pump motor/float switch.
NOTICE: If charger is connected backwards, pump will not operate properly, battery will not charge.
2.Plug in power cord to a
at least 2 amps. Do not use a switch controlled outlet. Mark circuit in main power panel =Backup sump pump power supply; do not turn off'.
BD
CI
1413 1194
Figure 4 - Battery Backup Control Panel
/L Battery depleted - charging current 10 amps.
B.Battery nearly charged - current about 5 amps.
C.Charge complete - current 0 amps, LED lights up.