13. Reinstall battery clamps:
A. Black switch wire damps to positive battery terminal.
B. Black pump wire clamps to negative battery terminal.
NOTICE: DO NOT reverse terminal connections.
14.Turn pump upside down; unclip and remove screen. Do
not remove
momentarily "bump _ pump. Check for correct operation
and rotation (pump must rotate
when looking at end of shaft - Figure 8). If not, reverse wires to battery and recheck.
15. Replace screen.
16.Plug in charger to wall outlet.
17.Fill sump with water and check switch action. Adjust tether if necessary.
IA CAUTION IDONOTtest run pump for more than
5 seconds without water in it. Running pump dry for
extended periods could damage pump and voids war-
ranty.
Craftsman Battery Backup Sump Pump
Model 390.306062
6A 6B
Battery Clamp
Brown
y Clamp
12
/
Negative
1412 1194
REPAIR PARTS LIST
Key No. | Part No. |
1
2
3
4
5
6A
6B
7 | PS |
8
10
11
12
Part Description
SwitchAssembly#
PumpComplete***
CordClamp
Fuse Holder
WireTerminal(4 Req.)
BatteryTerminalClamps(2 Req.)
BatteryCase (includesstrapand strapbrackets)
.Charger***
CheckValve
Hose Clamp1"min.- 2"max.S.S.
PipeAdapter
Tee
ReducerBushing(2 Red.)
#When ordering,also orderKeyNos. 4 (Fuse Holder)and 5 (Fuse) requiredfor installation. * Not illustrated.
** StandardHardwareItem;purchaselocally.
***No componentpartsavailablefor pumpor batterycharger.
1 Secondfuse issuppliedas spare.