Sears 390.306062 owner manual Craftsman Battery Backup Sump Pump Model, Repair Parts List

Models: 390.306062

1 8
Download 8 pages 6.6 Kb
Page 7
Image 7
Craftsman Battery Backup Sump Pump

13. Reinstall battery clamps:

A. Black switch wire damps to positive battery terminal.

B. Black pump wire clamps to negative battery terminal.

NOTICE: DO NOT reverse terminal connections.

14.Turn pump upside down; unclip and remove screen. Do

not remove screw-mounted bottom plate. Lift switch to

momentarily "bump _ pump. Check for correct operation

and rotation (pump must rotate counter-clockwise

when looking at end of shaft - Figure 8). If not, reverse wires to battery and recheck.

15. Replace screen.

16.Plug in charger to wall outlet.

17.Fill sump with water and check switch action. Adjust tether if necessary.

IA CAUTION IDONOTtest run pump for more than

5 seconds without water in it. Running pump dry for

extended periods could damage pump and voids war-

ranty.

Craftsman Battery Backup Sump Pump

Model 390.306062

6A 6B

Battery Clamp

Brown

y Clamp

12

/

Negative

1412 1194

REPAIR PARTS LIST

Key No.

Part No.

1PS217-5E

2PS17-41

3CC0030-13

4U17-1148

5U17-1149

6A

6B

PS17-100

7

PS 117-77A

8PS22-1

10PS78-3P

11U78-846P

12U78-876P

Part Description

SwitchAssembly#

PumpComplete***

CordClamp

Fuse Holder

15-AmpTime-DelayFuse(2 suppliedt)

WireTerminal(4 Req.)

BatteryTerminalClamps(2 Req.)

BatteryCase (includesstrapand strapbrackets)

.Charger***

CheckValve

Hose Clamp1"min.- 2"max.S.S.

PipeAdapter

Tee 1-1/2x 1-1/2x 1-1/4 PVC

ReducerBushing(2 Red.)

#When ordering,also orderKeyNos. 4 (Fuse Holder)and 5 (Fuse) requiredfor installation. * Not illustrated.

** StandardHardwareItem;purchaselocally.

***No componentpartsavailablefor pumpor batterycharger.

1 Secondfuse issuppliedas spare.

Page 7
Image 7
Sears 390.306062 owner manual Craftsman Battery Backup Sump Pump Model, Repair Parts List