Troubleshooting

Trouble

Unit will not run.

Unit will not shut off.

Unit will not dry out completely

I Bottles continue to empty.

Probable Cause

Humidity level is too high

No power

Float is not free

Water is present in the system

High humidity or low temperature resulting in slow evaporation

Air is entering water reser- voirs.

Remedy

Raise humidistat setting

Check 120 volt power source

Free float from obstruction

This is normal. A small

amount of water remains in

the cabinet.

• Allow unit to continue opera-

tion.

• Check "E-Z-Fill Side-Caps" to

ensure tightness.

Check for leak in water bottles.

• Are gaskets for "E-Z-Fill Side-

Caps" in place (see repair

parts list).

Unit is not emptying. • Dirty filter

Reservoir cap plunger missing post in bottom of cabinet.

Change

to a fresh

new filter.

Check

orientation of bottle.

 

Reposition

so

that

reservoir

 

cap

plunger

is

depressed by

 

post

in bottom

of cabinet.

Unit runs and shuts off before bottles are empty

!Humidity level is too high

Unit is not setup on a level surface (Float will not sense water at the rear of the cabinet.

• Raise humidistat setting (if

possible)

• Position unit level (Some car-

pet padding may allow unit to

set lower in the front than the

rear with the additional weight

of water bottles in the front of

the cabinet. Install coasters

under front casters.

CAUTION: Use only 42-14900EPA Registered Bactedostat available from

Sears Retail store.

Use of other water treatment products may damage the filter elements.

Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.