MAINTENANCE AND TROUBLE-SHOOTING
Inspectand tighten all parts of the CARDIO FIT PLUSregularly. Keep the monitor out of direct sunlightor the
displaymay be damaged. The CARDIO FIT PLUS canbe cleaned with asoft, damp cloth. Keep liquidaway from
themonitor. When storing the CARDIO FIT PLUS. remove the batteriesfrom the monitor,
HOW TO REPLACE THE BATrERIES
Ifthe display ofthe Monitor (1) becomes dim, the two L1154
watch batteries should be replaced.Lift the Monitoroff the
Frame (6): Disconnect the Sensor Wire (15) from the
Monitor. Remove the four screws from the back coverof the
Monitorand remove the back cover(see the inset drawing).
Push thetwo old batteries out ofthe battery clips,noting
whichway each battery isturned. Insert two new batteries.
Screws
Reattachthe back cover of the Monitor(1). Connect the
Sensor Wire (15) to the Monitor. Insert all excess wire into
the Frame (6). Press the Monitoronto the Frame.
HOW TO ADJUSTTHE MAGNET AND REED SWITCH
"If the monitordisplays incorl'eCtfeedback, the Magnet (27)
and the Reed Switch (15) shouk:lbechecked. Pivotthe Pedal
Frame (32) until the Magnet is alignedwith the Reed Switch.
Slightlyloosen the #8 x 3/4" Screw (18) inthe Reed Switch.
Slidethe Reed Switch slightlycloser tothe Magnet. Tighten
the #8 x 3/4" Screw. Exercise on the CARDIO FIT PLUS for a
moment. Repeat uhtilthe monitordisplays correct feedback.
Make sure that the Magnet does nothit the ReedSwitch.
HOW TO LUBRICATE THE CARDIO FIT PLUS
Everythree months, a small amountof light multi-purpose oil
shouldbe applied to the CARDIO FIT PLUS. Apply a few
dropsof oil between the dome capsand theframe in the
locationsshown at the right.Make sure to apply oilto both
sidesof the CARDIO FIT PLUS.
Apply Oil