Sears 150, 919 PROBLEM EnsUewdJnot=tart, Correct/On, No elecfK aloutput, Cause, Faultyep k p ug

Models: 329 150 919

1 32
Download 32 pages 6.99 Kb
Page 19
Image 19
PROBLEM EnsUewdJ'not=tart

ii

PROBLEM EnsUewdJ'not=tart

No elecfK_aloutput

Repeated circuit breaker tripping

Genorator overheating the circuit I_oaker depressed

i iii

n

ii

CAUSE

1.Low on fuel or o11.

2.Igrdtion switch In "Off'position.

3.Faultyep_k pug.

4.Choke In wrong position.

5.Fuel shut-off valve in do_md position.

8.Unit loaded during start-up.

7.Spark plug wire loose.

1.Faulty reaep_acla.

2, Circuit breaker kicked out.

3.Oefectlve capacitor.

4.Faulty power oord,

5.GFCI receptacle c/muir breaker kicked out.

1.Ovadoad

2.Faulty cords or equipment.

1.Generator overloaded.

2.Insufficient ventilation.

ii

CORRECT/ON

1.Add fuol or oil.

2.Tumto 'ON' polltlon

3.Replace spark plug.

4.Adjust choke accon:lingly.

5.Open fuel shut-off valve.

6, Remove load from unit.

7. Attach wire to spark plug.

1.HaveAuthodzed Sears Service

Center replace.

2.Depress and reset.

3.Have Authodzad Sears Service Centor replace capacitor,

4.Repair or replace cord.

S, Det_mw and _et.

1.Reduce load.

2.Cheokfor damaged,bare,or frayedwireson equipment. Replace.

1, R_uoaload.

2.Move to adequate supply of fresh air.