Small Packaged Products
Accessory Crankcase Heaters
Cancels: IlK | IlK |
|
|
Installation Instructions
PIN CPCRKHTR003A00, CPCRKHTR004A00
CPCRKHTR005A00, CPCRKHTR007A00
NOTE: Read the entire instruction manual before starting the installation.
This symbol _ indicates a change since the last issue.
SAFETY CONSIDERATIONS
Installing and servicing air conditioning equipment can be hazard-
ous due to system pressures, electrical components, and fuel gases.
Only trained and qualified personnel should install, service, or
repair air conditioning equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning coils, or cleaning and replacing filters. All other
operations should be performed by trained service personnel.
When working on air conditioning equipment, observe precautions
in the literature, on tags, and on labels attached to the unit.
Recognize safety information. This is the
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU
TION. These words are used with the safety alert symbol DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property danlage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or operation.
Follow all safety codes. Wear safety glasses and work gloves.
Have a fire extinguisher available.
INTRODUCTION
These instructions cover the installation of an Accessory Crank-
case Heater on Electric Cooling, Heat Pump and Electric
Cooling/Gas Ideating units.
_)DESCRIPTION AND USAGE
The accessory crankcase heater warms the compressor crankcase
oil to reduce refrigerant migration in the crankcase and ensure
proper compressor lubrication. Refer to Tables 1, 2 and 3.
INSTALLATION
1. | Turn | off gas | supply | (if | applicable) | first, | then | disconnect | |
| electric | power | supply. |
|
|
|
|
| |
2. | Install |
| Lockout | Tag, |
|
|
|
|
|
3. | Remove | access | panel | for | compressor | and | control | box. (See | |
| Fig. | 1.) |
|
|
|
|
|
|
Table
50JZ/602B (FACTORY INSTALLED ON
50GL/702B
UNIT SIZE | 240 V | 460 V |
024 | CPCRKHTR004A00 | NA |
030 | CPCRKHTR004A00 | NA |
036 | CPCRKHTROO4AO0 | CPCRKHTROO5AO0 |
042 | CPCRKHTROO4AO0 | CPCRKHTROOSAO0 |
048 | CPCRKHTR004A00 | CPCRKHTR005A00 |
060 | CPCRKHTROO4AO0 | CPCRKHTROO5AO0 |
Table 2--Accessory Crankcase Heater Usage
See Below for Units Applicable
| 48GS/582A/PY1 | |
| 50GS/701 A/PAt | |
UNIT SIZE | 240 V | 460 V |
018 | CPCRKHTR007A00 | NA |
024 | CPCRKHTR007A00 | NA |
030 | CPCRKHTR007A00 | NA |
036 | CPCRKHTR007A00 | CPCRKHTROO3AO0 |
O42 | CPCRKHTR007A00 | CPCRKHTROO3AO0 |
O48 | CPCRKHTROCAA00 | CPCRKHTROO5AO0 |
060 | CPCRKHTR007A00 | CPCRKHTR003A00 |
Table
UNIT SIZE | 240 V | 460V |
018 | CPCRKRTR007A00 | HA |
024 | CPCRKHTR007A00 | NA |
030 | CPCRKHTR007A00 | NA |
036 | CPCRKHTR007A00 | CPCRKHTR003A00 |
042 | CPCRKHTR004A00 | CPCRKHTR005A00 |
048 | CPCRKHTR004A00 | CPCRKHTR005A00 |
060 | CPCRKHTR004A00 | CPCRKHTR005A00 |
4.Spread crankcase heater arms and wrap heater around com-
pressor base approximately
5.Fasten heater firmly in place with fastening clip provided with
the crankcase heater. (See Fig. 1.1
6.Route crankcase heater leads into unit control box, following
the path of the compressor leads. (See Fig. 1.)
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 | PC 101 | Catalog No. | Printedin U.S.A. | Form | Pg 1 | 501 | Replaces: |