7. Masonry Chimney Venting

Chimney Inspection

All masonry chimney construction must conform to Standard ANSI/NFPA 211-2003 and to any state or local codes applicable. The chimney must be in good condition and a complete chimney inspection must be conducted prior to furnace installation. If the in-

spection reveals damage or abnormal conditions, make neces- sary repairs or seek expert help. See Figure 11 "The Chimney

Inspection Chart". Measure inside area of tile-liner and exact height of chimney from the top of the chimney to the highest ap- pliance flue collar or drafthood outlet.

Connector Type

To reduce flue gas heat loss and the chance of condensate prob-

lems, the vent connector must be double-wall Type B vent.

Venting Restrictions for Chimney Types

Interior Chimney - has no sides exposed to the outdoors below

the roofline. All installations can be single furnace or common vented with another draft hood equipped Category ] appliance.

Exterior Chimney - has one or more sides exposed to the out- doors below the roof line. All installations with a 99% Winter De-

sign Temperature* below 17°F must be common vented only with a draft hood equipped Category I appliance.

*The 99% Winter Design Dry-Bulb (db) temperatures are found in the 1993 ASHRAE Fundamentals Handbook, Chapter 24, Table 1 (United States) and 2 (Ca nada ), or use the 99.6% heating db temperatures found in the 1997 or 2001 ASHRAE Fundamentals Handbook, Climatic Design Information chapter, Table 1A (United States) and 2A (Canada).

CARBON MONOXIDE POISONING, FIRE AND EXPLOSION HAZARD.

Failure to properly vent this furnace could result in

death, personal injury and/or property damage.

These furnaces are CSA (formerly AGA and CGA)

design-certified for venting into exterior clay

tile-lined masonry chimneys with a factory accessory Chimney Adapter Kit. Refer to the furnace rating plate for correct kit usage. The Chimney Adapter Kits are for use with ONLY furnaces having a Chimney Adapter Kit number marked on the furnace rating plate.

Ira claytile-lined masonry chimney is being used and it is exposed to the outdoors below the roof line, relining might be required.

Chimneys shall conform to the Standard for Chimneys, Fire-

places, Vents, and Solid Fuel Burning Appliances ANSI/NFPA

211-2003 in the United States and to a Provincial or Territorial Building Code in Canada (in its absence, the National Building Code of Canada) and must be in good condition.

U.S.A.- Refer to Sections 13.1.9 or 13.2.20 of the N FGC or the au- thority having jurisdiction to determine whether relining is required. If relining is required, use a properly sized listed metal liner, Type-B vent, or a listed alternative venting design.

NOTE: See the NFGC, 13.1.9 and 13.2.20 regarding alternative venting design and the exception, which cover installations such as the Chimney Adapter Kits NAHAOOIDH and NAHAOO2DH.

The Chimney Adapter Kits are listed alternative venting designs

for these furnaces. See the kit instructions for complete details.

Canada (and U.S.A.)-This furnace is permitted to be vented into a clay tile-lined masonry chimney that is exposed to the outdoors below the roof line, provided:

1.Vent connector is Type-B double-wall, and

2.This furnace is common vented with at least 1 draft hood- equipped appliance, and

3.The combined appliance input rating is less than the maxi- mum capacity given in Table A, and

4.The input rating of each space-heating appliance is greater than the minimum input rating given in Table B for Masonry Chimneys for the local 99% Winter Design Temperature.

Chimneys having internal areas greater than 38 square inches require furnace input ratings greater than the input

ratings of these furnaces. See footnote at bottom of Table B, and

5.The authority having jurisdiction approves.

If all of these conditions cannot be met, an alternative venting de- sign shall be used, such as the listed chimney adapter kit with a

furnace listed for use with the kit, a listed chimney-lining system, or a Type-B vent.

These furnaces are CSA design-certified for use in exterior clay tile-lined masonry chimneys with a factory accessory Chimney Adapter Kit. Refer to the furnace rating plate for correct kit usage. The Chimney Adapter Kits are listed alternative venting designs and are for use with ONLY furnaces having a Chimney Adapter Kit number marked on the furnace rating plate.

441 01 2613 02

[_

Page 15
Image 15
Sears 8MPN100F14B1 Masonry Chimney Venting, Chimney Inspection, Failure to properly vent this furnace could result

8MPN125J20B1, N8MPL050B12B1, N8MPL100F20B1, 8MPN050B12B1, 8MPL075F16B1 specifications

Sears has long been recognized as a prominent name in the retail and home appliance industry, and its commitment to quality is evident in its range of products, including the N8MPN100F20B1, N8MPN100F14B1, 8MPL125J20B1, 8MPN100J20B1, and 8MPN075B12B1 models. These products combine advanced technology with user-friendly features to meet the demands of modern consumers.

The N8MPN100F20B1 and N8MPN100F14B1 models are equipped with innovative energy-saving technologies that help reduce electricity consumption while maintaining optimal performance. Both units feature robust insulation and efficient compressors designed for maximum cooling efficiency. They are also designed with smart controls, allowing users to customize their experience through programmable settings and remote access capabilities, ensuring comfort and convenience.

The 8MPL125J20B1 model stands out for its multipurpose functionality. This model is known for its impressive range of capabilities, making it suitable for various applications, from cooling to heating. Equipped with advanced thermal management systems, it ensures that the temperature remains consistent and comfortable, regardless of external conditions. This versatility, combined with an easy-to-use interface, makes it a favorite among households.

The 8MPN100J20B1 offers a sleek design paired with high-performance features. Its compact size makes it ideal for urban living spaces, while its quiet operation ensures minimal disruption. The model also boasts a high energy efficiency rating, aligning with modern sustainability trends. With its intuitive controls, users can easily adjust settings to match their preferences, ensuring a personalized environment.

Lastly, the 8MPN075B12B1 model is designed for those who value efficiency without sacrificing performance. This unit provides effective cooling solutions while being lightweight and easy to install. Its durable construction and reliability make it an excellent choice for both residential and commercial applications.

Overall, the Sears range of N8MPN and 8MPN models showcases the company’s focus on integrating technology with user convenience. Each unit is designed to deliver exceptional performance, energy efficiency, and versatility, making them essential additions to any home or office. With their advanced features and characteristics, these models demonstrate Sears' commitment to innovation and consumer satisfaction, reinforcing its legacy in the appliance industry.