MANIFOLDPRESSUREAND ORIFICE SIZE FOR HIGHALTITUDEAPPLICATIONS

NATURAL GAS MANIFOLD PRESSURE (" w.c.)

..............................................................

 

 

MEAN

ELEVATION FEET

ABOVE

SEA

LEVEL

 

 

 

 

HEATING

0 to

2001 to

3001

to

4001

to

5001 to

6001 to

7001 to

VALUE

2000

3000

4000

5000

6000

7000

8000

at ALTITUDE

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

BTU/CU. FT.

No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure

700

 

 

 

 

 

 

 

 

 

 

 

 

 

41

3.7

725

 

 

 

 

 

 

 

 

 

 

 

41

3.7

41

3.4

750

 

 

 

 

 

 

 

 

 

 

 

41

3.5

42

3.6

775

 

 

 

 

 

 

 

 

 

41

3.6

42

3,6

42

3.3

800

 

 

 

 

 

 

41

 

3.6

42

3.7

42

3.4

42

3.1

825

 

 

 

 

41

3.7

41

 

3.4

42

3,5

42

3,2

42

2.9

850

 

 

 

 

41

3.5

42

 

3.6

42

3.3

42

3.0

42

2.8

875

 

 

41

3.6

42

3,6

42

 

3.4

42

3,1

42

2,8

42

2.6

900

 

 

42

3,7

42

3,4

42

 

3.2

42

2,9

42

2,7

42

2.5

925

41

3.7

42

3.5

42

3.3

42

 

3.0

42

2,8

42

2.5

44

3.3

950

41

3.5

42

3,3

42

3,1

42

 

2.9

42

2,6

42

2,4

44

3.1

975

42

3.7

42

3.2

42

2.9

42

 

2.7

42

2.5

44

3.2

45

3.6

1000

42

3.5

42

3,0

42

2,8

42

 

2.6

42

2.4

45

3.7

45

3.4

1050

42

3.2

42

2.7

42

2.5

44

 

3.3

45

3.6

 

 

 

 

1100

43

3.6

42

2,5

44

3.2

45

 

3.6

_i_i_i_i_iiiiiiiiiiiiiiiiiiiiiiiiiii i ; ;%;iiiiiiiiiiiiiiiiiil;i;! iiiiiiiiiiiiiiiiiiiiiii¸¸;i ;i;i;i;i;i;i;i;iiiiiiiiiiiiiiiiiii!; iiiiiiiiiiiiiiiiiiiiiiiiiiii!¸i¸;¸;¸;¸;¸;¸;¸;¸;¸;i!ii!iiiililililiiii!ii! i!ii!ii

NOTE: Natural gas data is based on 0.60 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1-2002/NFPA 54-2002 or National Standard of Canada, Natural Gas And Propane Installation Code CSA B149.1-05.

iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii

i

i i

!ii i

i("i!w.c.)i! i! i!

i! i! i! i! i! i!

i! i! i! i! i! i! i! i!

 

 

 

LPG or

PROPANE

GAS MANIFOLD

 

PRESSURE

 

 

 

 

HEATING

VALUE

 

 

 

 

MEAN

ELEVATION

FEET ABOVE

SEA LEVEL

 

 

 

at ALTITUDE

0 to

 

2001 to

 

3001 to

 

 

4001 to

 

5001 to

6001 to

7001 to

 

BTU/CU.

FT.

2000

 

3000

 

4000

 

 

5000

 

6000

7000

8000

 

2500

10.0

 

10.0

 

9.0

 

 

10.0

 

9.4

8.5

10.0

 

Orifice

Size

#54

 

#54

 

#54

 

 

#55

 

#55

#55

#56

NOTE: Propane data is based on 1.53 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1-2002/N FPA

54-2002 or National Standard Of Canada, Natural Gas And Propane Installation Code CSA B149.1-05.

 

 

NOTE:

The derating of these

furnaces

at 2% (Natural

Gas) and

4%

(Propane Gas)

has

been tested

and design-certified

by CSA.

In Canada, the input rating must be derated 5% (Natural Gas) and 10% (Propane Gas) for altitudes of 2,000 to 4,500 above sea level. Use

the 2001 to 3000 column in Table 6 and Table 7.

 

 

 

 

 

 

 

 

 

 

The burner orifice part nos. are as follows:

 

 

 

 

_

; ;;;

_ ;;;;;;; ;;;;;;;;;;;;;;;;;;2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

#41

1096942

Orifice

#42

 

1011351

 

 

 

 

 

Manifold

 

 

Orifice

#43

1011377

Orifice

#44

 

1011352

 

 

 

 

 

 

 

 

Orifice

#45

1011353

Orifice

#54

 

1011376

 

 

 

 

 

 

 

 

Orifice

#55

1011354

Orifice

#56

 

1011355

 

 

 

 

 

 

 

 

High Altitude Air Pressure Switch

The factory-installed pressure switch need NOT be changed for any furnace installations from sea level up to and including 8,000' altitude

Changing Orifices

1.After disconnecting power and gas supply to the furnace, re-

move the burner compartment door, exposing the burner compartment.

2.Disconnect gas line from gas valve so manifold can be re- moved.

3.Disconnect wiring at gas valve. Be sure to note the proper location of all electrical wiring before being disconnected.

4.Remove the four (4) screws holding the manifold and gas valve to the manifold supports. Do not discard any screws.

See Figure 35.

Some Models may vary

25-25-00

5.Carefully remove the manifold assembly.

6.Remove the orifices from the manifold and replace them with proper sized orifices. See Figure 36.

7.Tighten orifices so they are seated and gas-tight. See Figure 36.

8.Reassemble all parts in reverse order as removed. Be sure to engage the main burner orifices in the proper openings in the burners.

441 01 261302

[_

Page 29
Image 29
Sears N8MPN075F16B1, N8MPL100F20B1 I! i! i I! i! i! i! i, Changing Orifices, High Altitude Air Pressure Switch

8MPN125J20B1, N8MPL050B12B1, N8MPL100F20B1, 8MPN050B12B1, 8MPL075F16B1 specifications

Sears has long been recognized as a prominent name in the retail and home appliance industry, and its commitment to quality is evident in its range of products, including the N8MPN100F20B1, N8MPN100F14B1, 8MPL125J20B1, 8MPN100J20B1, and 8MPN075B12B1 models. These products combine advanced technology with user-friendly features to meet the demands of modern consumers.

The N8MPN100F20B1 and N8MPN100F14B1 models are equipped with innovative energy-saving technologies that help reduce electricity consumption while maintaining optimal performance. Both units feature robust insulation and efficient compressors designed for maximum cooling efficiency. They are also designed with smart controls, allowing users to customize their experience through programmable settings and remote access capabilities, ensuring comfort and convenience.

The 8MPL125J20B1 model stands out for its multipurpose functionality. This model is known for its impressive range of capabilities, making it suitable for various applications, from cooling to heating. Equipped with advanced thermal management systems, it ensures that the temperature remains consistent and comfortable, regardless of external conditions. This versatility, combined with an easy-to-use interface, makes it a favorite among households.

The 8MPN100J20B1 offers a sleek design paired with high-performance features. Its compact size makes it ideal for urban living spaces, while its quiet operation ensures minimal disruption. The model also boasts a high energy efficiency rating, aligning with modern sustainability trends. With its intuitive controls, users can easily adjust settings to match their preferences, ensuring a personalized environment.

Lastly, the 8MPN075B12B1 model is designed for those who value efficiency without sacrificing performance. This unit provides effective cooling solutions while being lightweight and easy to install. Its durable construction and reliability make it an excellent choice for both residential and commercial applications.

Overall, the Sears range of N8MPN and 8MPN models showcases the company’s focus on integrating technology with user convenience. Each unit is designed to deliver exceptional performance, energy efficiency, and versatility, making them essential additions to any home or office. With their advanced features and characteristics, these models demonstrate Sears' commitment to innovation and consumer satisfaction, reinforcing its legacy in the appliance industry.