Ventdampersonanyapplianceconnectedto the common vent

can cause condensation and corrosion in the venting system. Do not use vent dampers on appliances common vented with this fur- nace.

8. Gas Supply and Piping

Gas Piping Requirements

CARBON MONOXIDE POISONING, FIRE AND EXPLOSION HAZARD.

NOTE: The gas supply line must be installed by a qualifted service technician in accordance with all building codes.

NOTE: In the state of Massachusetts.

Failure to follow safety warnings exactly could result in serious injury, death, and/or property damage.

Models designated for Natural Gas are to be used with Natural Gas ONLY, unless properly converted to use with LP gas.

Gas Supply Requirements

Use only the Type of gas approved for this furnace. See rating plate for approved gas type.

Gas input must not exceed the rated input shown on the rating plate. Overfiring will result in failure of heat exchanger and cause dangerous operation.

Do not allow minimum supply pressure to vary downward. Do- ing so will decrease input to furnace. Refer to Table 3 for gas supply. Refer to Table 6 and Table 7 for manifold pressures.

I Gas Pressures

Gas Type

Supply

Pressure

 

Recommended

Max.

Min,

 

Natural

7"

14"

4.5"

Propa ne

11"

14"

11"

 

Typical Gas Piping (N8MP)

a.Gas supply connections MUST be performed by a li- censed plumber or gas fitter).

b.When flexible connectors are used, the maximum length shall not exceed 36" (915 mm).

c.When lever handle type manual equipment shutoff valves are used, they shall be T-handle valves.

d.The use ofcopper tubing for gas piping is NOT approved.

1.Install gas piping in accordance with local codes, or in the ab- sence of local codes, the applicable national codes.

2.It is recommended that a manual equipment shutoff valve be installed in the gas supply line outside the furnace. Locate valve as close to the furnace as possible where it is readily ac- cessible. Refer to Figure 12.

FIRE HAZARD

Failure to follow safety warnings exactly could result in death or personal injury.

Use wrench to hold furnace gas control valve when turning elbows and gas line to prevent damage to the gas control valve and furnace.

Drip Leg and Union, Union*

should be outside the

 

Manual shut- off

cabinet. Manual shut- off valve MUST be upstream

of

 

dripleg, union, and furnace.

 

 

valve

Alterative

Use elbows and 3" pipenipple to connectvalveto piping when using right side gas pipe entry. _.

LP Low pressure

3'pipe

switch.

 

25-24-86

* Union may be installed inside the cabinet when necessary because of clearances.

3. Useblackironorsteelpipeandfittingsorotherpipeapproved

4. Use

pipe thread compound which is resistant to natural and

by local code.

LP

gases.

_]

441 01 261302

Page 18
Image 18
Sears 8MPN125J20B1 Gas Supply and Piping, Ventdampersonanyapplianceconnectedto the common vent, Gas Pressures

8MPN125J20B1, N8MPL050B12B1, N8MPL100F20B1, 8MPN050B12B1, 8MPL075F16B1 specifications

Sears has long been recognized as a prominent name in the retail and home appliance industry, and its commitment to quality is evident in its range of products, including the N8MPN100F20B1, N8MPN100F14B1, 8MPL125J20B1, 8MPN100J20B1, and 8MPN075B12B1 models. These products combine advanced technology with user-friendly features to meet the demands of modern consumers.

The N8MPN100F20B1 and N8MPN100F14B1 models are equipped with innovative energy-saving technologies that help reduce electricity consumption while maintaining optimal performance. Both units feature robust insulation and efficient compressors designed for maximum cooling efficiency. They are also designed with smart controls, allowing users to customize their experience through programmable settings and remote access capabilities, ensuring comfort and convenience.

The 8MPL125J20B1 model stands out for its multipurpose functionality. This model is known for its impressive range of capabilities, making it suitable for various applications, from cooling to heating. Equipped with advanced thermal management systems, it ensures that the temperature remains consistent and comfortable, regardless of external conditions. This versatility, combined with an easy-to-use interface, makes it a favorite among households.

The 8MPN100J20B1 offers a sleek design paired with high-performance features. Its compact size makes it ideal for urban living spaces, while its quiet operation ensures minimal disruption. The model also boasts a high energy efficiency rating, aligning with modern sustainability trends. With its intuitive controls, users can easily adjust settings to match their preferences, ensuring a personalized environment.

Lastly, the 8MPN075B12B1 model is designed for those who value efficiency without sacrificing performance. This unit provides effective cooling solutions while being lightweight and easy to install. Its durable construction and reliability make it an excellent choice for both residential and commercial applications.

Overall, the Sears range of N8MPN and 8MPN models showcases the company’s focus on integrating technology with user convenience. Each unit is designed to deliver exceptional performance, energy efficiency, and versatility, making them essential additions to any home or office. With their advanced features and characteristics, these models demonstrate Sears' commitment to innovation and consumer satisfaction, reinforcing its legacy in the appliance industry.