- CARE OF YOUR HOME DRINKING WATER SYSTEM -
7.Install the RO housing, push downward and rotate 900 clockwise to lock in place.
8.Replace the tank shutoff valve and rotate 900 to lock.
9.Using the
10.DO THE SANITIZING AND PURGING PRO-
CEDURES, PAGE 10.
AUTOMATIC SHUTOFF SERVICE
If the shutoff assembly, on the RO cap, requires ser- vice, reassemble parts exactly as shown in FIG. 10. Be sure to align indicated marks to properly torque cap to RO cap.
arrow
RO cad
alignphragm
holes
plunger support
- plunger
Lphragm
p support
marko-ring
WHEN INSTALLING CAP,
TIGHTEN BY HAND.
THEN, USE A PLIERS
TO TIGHTEN AND ALIGN
MARK ON CAP WITH
ARROW ON RO CAP
SANITIZING THE RO SYSTEM
Sanitizing is recommended upon installation of the RO system, and after servicing inner parts of the RO housing, and cap. IT IS IMPORTANT FOR THE
SERVICE PERSON TO HAVE CLEAN HANDS
WHILE HANDLING INNER PARTS OF THE
SYSTEM.
1.BE SURE WATER SUPPLY TO THE RO IS TURNED OFF, AND THE RO FAUCET IS OPEN.
2.Remove the clamp retainers and clamp sections, Fig, 9, page 13.
3.Lift the cap from the RO housing (no need to disconnect tubing) and move aside.
NOTE: IF THE CAP
4.Remove the RO cartridge and prefilter car- tridge from the RO housing. If needed, flush hous- ing with fresh, clean water.
5.Fill the RO housing, with fresh water, to about 1 inch from the top. Add 1.0 oz. of chlorine (ordinary 5,25% household bleach... Hilex, Clerox, etc.) and mix in the water. DO NOT ADD CHLORINE FIRST.
Concentrated, it will attack plastics,
6.Replace the cap, with
7.Connect the RO faucet product water tubing directly to the tank shutoff valve, isolatinq the car- bon postfilter.
8.Open the tank shutoff valve, and the water supply to the RO. Open the RO faucet, locking the lever upward, against the spout.
9.Allow water to circulate through the system un- til the bleach odor is gone.
10.Turn off the water supply to the RO. Close the RO faucet after water flow stops.
11.Reconnect the postfilter (replace used filter) to the RO system, Fig. 9, page 13.
12a. Do steps 2 and 3.
b. Replace the RO cartridge and prefilter car- tridge (BE SURE YOUR HANDS ARE CLEAN).
c. Do step 6.
d. Turn to page 10 and do the pressure testing and purging steps B through E.
15