ELECTROMAGNETIC LOCK Installation Manual
TROUBLESHOOTING
Problem: | Possible cause: | Solutions: |
|
|
|
Door does not lock | No power | • Check to make sure the wires are |
|
| securely tightened to the terminal block |
|
| • Check that the power supply is connected |
|
| and operating |
|
| • Make sure the lock switch is wired |
|
| correctly |
|
|
|
Door locks, but can be | Poor contact between | • Make sure the electromagnet and |
easily forced open | electromagnet and | armature plate are properly aligned |
| armature plate | • Make sure the contact surfaces of the |
|
| electromagnet and armature plate are |
|
| clean and free from rust |
|
|
|
| Incorrect voltage | • Check the power leads with a meter, and |
| setting | make sure 12VDC or 24VDC is present |
|
|
|
Delay in door releasing | A secondary diode was | • The electromagnet is fitted with a metal |
| installed across the | oxide varistor to prevent interference, so |
| electromagnet | do not install a secondary diode |
|
|
|
REGULAR MAINTENANCE
•Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non- abrasive,
•Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.
•Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
•Check that the electromagnet is securely attached to the door frame.
UL CERTIFICATION
WARRANTY: ENFORCER Electromagnetic Locks are warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original customer. Our obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation
NOTICE
The information and specifications printed in this manual are current at the time of publication. However, the
Copyright © 2003
|
|
16842 Millikan Avenue, Irvine, CA 92606 | Website: |
Tel: |
® PITGW1
Page 4 |