Installation:

ENFORCER Wireless Request-to-Exit Plates

Installation:

1.Find a suitable location for the wireless request-to-exit plate.

NOTE: Do not house the plate in a metal box, this will greatly reduce the range.

2.The wireless request-to-exit plate can be either surface mounted or flush mounted.

3.Test the operation of the wireless request-to-exit plate in the location where it will be installed.

NOTE: The wireless request-to-exit plate first needs to programmed into the SK-910R receiver before testing. See SK-910R receiver manual for transmitter learning procedure.

4.Check and make sure the battery clip is securely connected. Then mount the wireless request- to-exit plate in the back-box and secure it with the 2 included screws.

Changing the Battery:

The wireless request-to-exit plate has multi-colored LED that illuminates blue when the button is pressed. When the battery begins to run low, the LED will illuminate red. To change the battery:

1.Remove the 2 screws from the front of the plate and remove the plate from the back-box.

2.Remove the battery clip from the 9V battery and remove the battery from the bracket.

3.Place the new battery in the bracket and snap the battery clip to the new battery.

4.Test the unit with the new battery. The LED should illuminate blue.

5.Put the plate back in the housing and secure it to the back-box using the screws on the front.

Sample Application: Connecting to multiple wireless devices to an Electromagnetic Lock:

 

 

 

 

 

SK-919TDWS-BU

 

 

 

 

 

Wired 1-channel

 

 

 

 

 

Transmitter

 

 

SK-910R

 

 

 

 

 

Wireless Receiver

 

 

E-964-Q660Q

 

 

 

 

 

 

 

 

 

 

 

Red=Low Battery

 

 

 

 

 

Quad Photobeam

SD-8202GT-PEQ

 

 

 

 

 

Detectors

Wireless

 

 

 

 

 

 

Request-to-Exit Plate

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

 

ENFORCER

 

 

 

 

 

 

SK-919TP4H-N

E-941SA-1200

 

SK-919TP4D-P

Hand-held 4-Button

 

Wireless 4-Button

Electromagnetic Lock

 

Transmitter

 

Desktop Transmitter

 

 

 

 