Henny Penny OFE/OFG-342 Gas Units Continued, and remove the high limit from bracket, Figure

Models: OEA/OGA-341 OEA/OGA-342 OFE/OFG-341 OFE/OFG-342

1 82
Download 82 pages 31.46 Kb
Page 12
Image 12
(Gas Units) (Continued)

Model OFE/OFG/OEA/OGA-341, 342

1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing

LIMIT CONTROLthe inner heat shield and remove from unit. Figure 2-3.

(Gas Units) (Continued)

Figure 2-3

3. Remove the screw securing the high limit bracket to the frame

 

and remove the high limit and bracket from unit. Figure 2-4.

Figure 2-4

4. Remove the two screws securing the high limit to the bracket

 

and remove the high limit from bracket.

5.Remove the two electrical wires from the high temperature limit control. Figure 2-5.

Figure 2-5

6.Manually reset the control, then check for continuity between the two terminals after resetting the control. If the circuit is open, replace the control, then continue with this procedure. (If the circuit is closed, the high limit is not defective. Re- connect the two electrical wires.)