2-8. FLAME SENSOR/ PILOT / IGNITOR ASSEMBLY (Gas) (Continued)

2.Remove the control panel and heat shield from control area. Figure 2-19.

Figure 2-19

3.Disconnect the flame sense wire from ignition module. Figure 2-20.

Figure 2-20

4.Using a 7/16” wrench, loosen the nut on the pilot tube and pull tube from assembly. Figure 2-21.

Figure 2-21

5.Remove the two screws securing the assembly and pull assembly from unit. Figure 2-22.

6.Now the flame sensor or or pilot assembly can be removed from bracket.

Figure 2-22

2-8