2-3. HIGH TEMPERATURE

 

 

Model OFE/OFG/OEA/OGA-341, 342

2-3. HIGH TEMPERATURE

 

 

LIMIT CONTROL

 

 

(Gas Units) (Continued)

 

 

Replacement

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

 

 

breaker, or unplug cord at wall receptacle.

 

1.

If the tube is broken or cracked, the control opens, shutting

 

 

off electrical power to the heat circuit. The control cannot be

 

 

reset, and it continuously clicks when pushed.

 

2.

Drain the shortening from the frypot and discard. A substance

 

 

from the tube could contaminate the shortening.

Figure 2-6

3.

Remove the control panel.

 

4.

Using a 5/16” wrench, loosen small inside screw nut on

 

 

capillary tube. Figure 2-6.

 

5.

Using a 11/16” crows-foot, remove the larger nut securing the

 

 

capillary tube to the pot. Figure 2-7.

Figure 2-7

6.

Remove the two screws securing the high limit guard and

 

remove guard. Figure 2-8

 

7.

Straighten the capillary tube inside the frypot, and pull the

 

 

capillary tube through the frypot, from behind the control

 

 

panel. Remove the defective high limit from the control panel

 

 

area.

 

8.

Replace new high limit in reverse order.

Figure 2-8

 

 

 

 

To avoid electrical shock or other injury, run the

 

 

capillary line under and away from all electrical power

 

 

wires and terminals. The tube must never be in such a

 

 

position where it could accidentally touch the electrical

 

 

power terminals.

1003

 

2-3

Page 13
Image 13