1-4. ERROR CODES

 

 

 

 

(Continued)

 

 

 

 

 

 

 

 

 

 

 

DISPLAY

 

CAUSE

PANEL BOARD CORRECTION

 

 

“E-20 A”

 

Vacuum

Press the timer button to try the ignition process again,

 

 

 

switch failure

and if “E-20 A” persists, check the air switch per Vacuum

 

 

 

(stuck closed)

Switch Section

 

 

 

 

 

 

 

 

 

“E-20 B”

 

Draft fan or

Press the timer button to try the ignition process again,

 

 

 

vacuum

and if “E-20 B” persists, check the vacuum switch per

 

 

 

switch failure

Vacuum Switch Section or the blower motor per Blower

 

 

 

(stuck open)

Motor Assembly Section

 

 

 

 

 

 

 

 

 

“E-20 C”

 

Ignition modules

Press the timer button to try the ignition process again; if

 

 

 

not responding

“E-20 C” persists, check the ignition module per Ignitor

 

 

 

 

Module Section, the spark ignitor per Pilot/Ignitor

 

 

 

 

Assembly Section, or the I/O board per Control & I/O

 

 

 

 

Boards Section

 

 

 

 

 

 

 

 

 

“E-20 D”

 

Pilots not lit or

Press the timer button to try the ignition process again; if

 

 

 

no flame sense

“E-20 D” persists, check the ignition module per Ignition

 

 

 

 

Module Section, the I/O board per Control & I/O Boards

 

 

 

 

Section, or the flame sensor per Flame Sensor Section

 

 

 

 

 

 

 

 

“E-47”

 

Analog converter

Turn switch to OFF, then back to ON;

if “E47” persists,

 

 

 

chip or 12 volt

replace the I/O board, or the PC board;

if speaker

 

 

 

supply failure

tones are quiet, probably I/O board failure

 

 

 

 

 

 

 

 

“E-48”

 

Input system

Replace PC board

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

“E-70”

 

Faulty power

Check power switch, along with its wiring;

 

 

 

switch or switch

replace I/O board if necessary

 

 

 

 

 

wiring; faulty I/O

 

 

 

 

 

 

board

 

 

 

 

 

 

 

 

 

 

“E-92”

 

24 VAC fuse

Check for shorted component in 24 volt circuit;

 

 

 

on I/O open

(i.e., high limit, drain switch, vacuum switch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 