Henny Penny OFE/OFG-342, OFE/OFG-341 Troubleshooting, Continued, Problem, Cause, Correction

Models: OEA/OGA-341 OEA/OGA-342 OFE/OFG-341 OFE/OFG-342

1 82
Download 82 pages 31.46 Kb
Page 8
Image 8
1-2. TROUBLESHOOTING

 

 

 

Model OFE/OFG/OEA/OGA-341, 342

1-2. TROUBLESHOOTING

 

 

 

(Continued)

 

 

 

 

 

 

 

PROBLEM

CAUSE

CORRECTION

 

 

 

 

 

Shortening will not

Drain valve clogged

Open valve, force cleaning brush through

 

drain from frypot

with crumbs

drain

 

 

Drain valve will not

Replace cotter pins in valve coupling

 

 

open by turning

 

 

 

handle

 

 

 

 

 

 

Filter motor runs

Pump clogged

Remove pump cover and clean

 

but pumps shortening

Filter line connection

Tighten all filter line connections

 

slowly

 

 

loose

 

 

 

Solidified shortening

Clear all filter lines of solidified shortening

 

 

in lines

 

 

 

 

 

 

Filter switch on,

Defective switch

Check/replace switch per Filter Switch

 

motor does not run

 

Section

 

 

Defective motor

Check/replace motor

 

 

Motor thermal

Reset thermal switch on filter motor

 

 

protector tripped

 

 

 

 

 

 

Motor hums but

Clogged lines or

Remove and clean pump and lines

 

will not pump

pump

Replace pump seal, rotor and rollers

 

 

 

 

 

 

 