2-18. HEATING CONTACTORS (ELECTRIC) (Continued)

Model OFE/OFG/OEA/OGA-341, 342

2-18. HEATING CONTACTORS (ELECTRIC) (Continued)

To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit breaker closed and the main power switch in the ON position.

 

1. Re-apply power to unit and turn power switch to ON.

 

2. Using illustrations from previous page, check voltage as

 

follows:

 

 

Test Points

Results

 

Heat Contactor

 

 

From terminal 34 to 35

The voltage should read

 

From terminal 35 to 36

the same at each terminal

 

From terminal 34 to 36

 

 

Test Points

 

 

Primary Contactor

 

 

From terminal 27 to 28

It should correspond to the

 

From terminal 28 to 29

voltage stated on the data

 

From terminal 27 to 29

plate.

Replacement

If neither contactor is defective it must be replaced as follows:

(Heat Contactor)

 

 

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other control on 2-frypot units will have power.

Figure 2-54

1. Remove only the wires directly connected to the contactor

being replaced. Label the wires for replacement. Figure 2-54.

2-20

1003

Page 30
Image 30
Henny Penny OEA/OGA-342, OFE/OFG-342 HEATING CONTACTORS ELECTRIC Continued, Heat Contactor, Replacement, Figure