Henny Penny OEA/OGA-341 terminals, High Temperature, LIMIT CONTROL ELECTRIC Continued, Figure

Models: OEA/OGA-341 OEA/OGA-342 OFE/OFG-341 OFE/OFG-342

1 82
Download 82 pages 31.46 Kb
Page 35
Image 35
terminals

Model OFE/OFG/OEA/OGA-341, 342

2-20. HIGH TEMPERATURE

LIMIT CONTROL (ELECTRIC) (Continued)

 

4.

Straighten the capillary tube, and pull capillary tube through

 

 

the hole in the element hinge, from the rear of the fryer.

 

5.

Remove the defective control from the fryer.

Figure 2-69

6.

Straighten the capillary tube on the new high limit, and thread

 

 

the capillary tube through the hole in the element hinge.

 

 

Figure 2-69.

 

7.

Reattach the capillary to the brackets on the upper and lower

 

 

parts of the elements.

 

 

DO NOT crimp or kink the capillary tube during installation.

 

 

Also, keep capillary tube behind element to protect from

 

 

damage from the basket or during cleaning. Damage to the

 

 

capillary tube reduces the life of the high limit, or causes the

 

 

high limit to fail.

 

8.

Connect wires to new high limit body and fasten to bracket,

 

 

using the two screws removed in the checkout part of this

 

 

section.

 

 

Make sure red reset button of high limit lines up with the

 

 

plunger that inserts into the element hinge.

 

 

To avoid electrical shock or other injury, run the capillary

 

 

line under and away from all electrical power wires and

 

 

terminals. The tube must never be in such a position

 

 

where it could accidentally touch the electrical power

 

 

terminals

 

9.

Re-install the rear cover and unit is now ready for use.

1003

 

2-25

Page 35
Image 35
Henny Penny OEA/OGA-341, OFE/OFG-342, OFE/OFG-341 terminals, High Temperature, LIMIT CONTROL ELECTRIC Continued, Figure