Henny Penny OEA/OGA-342 Filter Switch, Replacement, Remove electrical power supplied to the unit

Models: OEA/OGA-341 OEA/OGA-342 OFE/OFG-341 OFE/OFG-342

1 82
Download 82 pages 31.46 Kb
Page 22
Image 22
2-14. FILTER SWITCH

Model OFE/OFG/OEA/OGA-341, 342

2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should

REPLACEMENT “open”, cutting off the pilot flame. This will prevent the fryer from heating while shortening is being drained from the frypot.

1.Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.The following check should be made to determine if the drain microswitch is defective.

a. Remove the two screws and nuts securing the microswitch

Figure 2-32to the drain rod valve bracket, and remove microswitch. Figure 2-32.

b.Remove wires from the switch. Figure 2-33.

c.Check for continuity across the two outside terminals of the drain switch. If the circuit is open, the drain switch is defective. The circuit opens by pressing on the actuator of the microswitch.

3.If defective, replace switch in reverse order.

Figure 2-33

2-14. FILTER SWITCH

 

REPLACEMENT

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Figure 2-34

2. Open the door (left door on 2 well units), and remove the 2

screws securing the switch box cover. Figure 2-34.