Digital Access Keypad Manual

INSTALLER PROGRAMMING

These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.

Enter Programming Mode

 

(DEFAULT: 0 0 0 0 )

Enter Master code

Confirm

Function

X X X X *

 

*

 

Enter into programming mode

*Key in the Master Code.

 

 

Note: For first-time use, Master code is

0 0 0 0

 

 

 

 

Data Refresh

 

 

 

Option

 

Confirm

Function

 

 

8

9 0

1

#

Clears all previously stored data.

 

 

 

Configure Relay Outputs

 

(DEFAULT: Momentary, 1-sec. output for all three outputs)

Option

Output time

Confirm

Function

4

0

1 to 999

 

#

Relay #1, momentary mode, from 1 to 999 seconds

4

1

 

 

 

#

Relay #1, shunt mode (ON/OFF)

5

0

1 to 999

 

#

Relay #2, momentary mode, from 1 to 999 seconds

5

1

 

 

 

#

Relay #2, shunt mode (ON/OFF)

6

0

1 to 999

 

#

Output #3, momentary mode, from 1 to 999 seconds

6

1

 

 

 

#

Output #3, shunt mode (ON/OFF)

 

 

 

 

Wrong Code Lockout

 

 

(DEFAULT: 10 tries / 30 seconds)

Option

# of tries

Confirm

Function

7

0

 

 

 

After 10 successive wrong codes, 30-second lockout

7

1

 

 

 

After 10 successive wrong codes, Duress activated

7

2

5 to 10

#

After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code

7

6 0

0

 

#

None of the above

 

 

 

Door Forced-Open Alarm

 

(DEFAULT: Disabled)

Option

Code entry

Confirm

Function

8

0

{

1

#

Door forced-open alarm is enabled

0

#

Door forced-open alarm is disabled

 

 

 

 

 

Output Activation Announcer

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

 

 

{

1

#

1-sec. beep notifies the user to open the door when the output relay is activated with the

8

1

 

 

user code or egress button. Use with a locking device which gives no sound when it

 

 

activates, such as a magnetic lock.

 

 

 

 

 

 

0

#

The beep is disabled, replaced by 2 short beeps for valid user codes.

 

 

 

 

User Code Entry Mode

 

 

(DEFAULT: Manual)

Option

Code entry

Confirm

Function

 

 

{

1

#

Auto Entry Mode is selected. The # key that follows the user code is NOT required in

8

2

 

 

code entry. The User Codes MUST be set to the same digit length as the Master Code,

 

 

from 4-8 digits.

 

 

 

 

 

 

0

#

Manual Entry Mode is selected. The # key that follows the user code is required in

 

 

 

 

 

code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.

 

 

 

 

Keypress Beeps

 

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

8

3

{

1

#

Keypad beeps when a key is pressed.

0

 

Silent operation -- keypad does not beep when a key is pressed.

 

 

#

 

 

 

Door Propped Open Alarm Timer

 

(DEFAULT: Off)

Option

Code entry

Confirm

Function

9

 

 

0

#

No door propped open alarm

 

{1 to 999

#

Allowable time from 1 to 999 seconds that the door can be left open before the door

 

 

propped open alarm starts

Exit Programming Mode

Confirm Function

*Exits programming mode, returns keypad to normal operations

Digital Access Keypad Manual

UNIQUE FEATURES

12-24V AC/DC universal power -- No programming or jumpers needed.

Mantrap -- Each keypad can be used as a stand-alone keypad. However, the mantrap feature uses two keypads to protect an area with two doors by ensuring that only one door is open at a time. With the mantrap interlock functions, when a user keys in the code to open one door, a signal is sent to disable the second keypad, thereby preventing access through the second door until the first door is closed.

Relay output #1 inhibit control -- Relay output #1 is typically used for a door strike. If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This increases the security of the protected premises during the time it is not expected to be occupied, such as during evening or weekend hours. An authorized user can enable or disable the inhibit control by using the code for relay output #2 or output #3 at any time, depending on how installed.

Door forced open warning -- When used with an optional magnetic contact, the keypad beeps continuously for 1 minute if the door to the protected premises is forced open without using a valid user code. The warning can be stopped at anytime by keying in any output #1 user code.

Door propped open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door is propped open after the allowed open time. The allowable open time is programmable. The warning stops when the door is re- closed.

Auto or manual code entry checking:

o Auto code entry checking mode -- When all the user codes have the same number of digits, the keypad will activate automatically when the code is entered. There is no need to press the "#" key. This is convenient for the users.

o Manual code entry checking mode -- The user codes can vary in number of digits, and the user must press the "#" key when finished entering the code. This increases security.

Keypad active output -- This NPN transistor open collector ground (-) output activates for 10 seconds when any key on the keypad is pressed. This can be used to trigger a video recorder or turn on a light, or to signal a guard that someone is entering the protected premises.

Alarm output -- When used with an optional magnetic contact, this NPN transistor open collector ground (-) output can be connected to trigger an optional alarm control panel if a protected door is forced open or propped open.

Door auto relock -- This can be programmed to relock an open door either when the programmed relock time expires or immediately after the door is closed, depending on which occurs first. This prevents unwanted "tailgate" entries, which can happen if an unauthorized person tries to follow an authorized person through the door.

Duress output -- This NPN transistor open collector ground (-) output can be used to trigger a silent alarm if an authorized user is forced under duress to use the keypad. The duress output is activated by adding 2 to the first digit of any user code for output #1. In this case, the protected door opens as it would normally, but a signal is quietly sent to a remote device to call for help without alerting the unauthorized person.

Backlit keypad -- The keypad is backlit to increase nighttime visibility. For convenience, the lighting intensity will increase for 10 seconds after any key is pressed.

Page 14

SECO-LARM U.S.A., Inc.

Page 3

 

Page 3
Image 3
SECO-LARM USA SK-1131-SQ warranty Installer Programming, Unique Features, Auto or manual code entry checking

SK-1131-SQ specifications

The SECO-LARM USA SK-1131-SQ is an innovative security solution designed for various applications, offering advanced technology in a compact and efficient package. This product is primarily a standalone access control unit that integrates a multitude of features tailored to enhance security while being user-friendly.

One of the main characteristics of the SK-1131-SQ is its keypad, which allows users to enter a unique code for access purposes. The unit supports up to 1000 different user codes, enabling a high level of accessibility for both individuals and organizations. This feature is particularly beneficial for businesses that require different levels of access for employees, allowing for easy management of access rights.

In addition to its keypad functionality, the SK-1131-SQ includes a built-in proximity reader. This reader is compatible with a range of RFID cards and fobs, facilitating a seamless entry experience for users. The dual authentication method—a code and RFID—enhances security by reducing the risk of unauthorized access through simple code sharing.

The SECO-LARM SK-1131-SQ is designed with durability in mind, featuring a weather-resistant casing that allows it to be installed in outdoor settings without compromising its functionality. This robustness makes it a reliable choice for various environments, whether for residential homes or commercial premises.

Another notable technology feature is the option for a relay output, which can be interfaced with existing access control systems. This feature promotes flexibility, allowing the SK-1131-SQ to be integrated into broader security systems, including alarms and surveillance cameras.

Moreover, the SK-1131-SQ operates on a low power consumption model, ensuring minimal energy use while providing maximum performance. The unit can function in a range of temperatures, highlighting its adaptability to different climates and conditions.

Installation is straightforward, as the unit supports a simple wiring process and can be mounted on various surfaces. Users can easily program the device using the built-in functions for rapid setup, making it a practical choice for security professionals and end-users alike.

Overall, the SECO-LARM USA SK-1131-SQ is a versatile and innovative security solution. With its combination of advanced features, robust design, and flexible application possibilities, it stands out as a reliable and efficient access control unit for diverse security needs.