Installation
∙Note: The oven cavity must vent through the front only. Avoid gaps between cupboard sides and the underside of the worktop.
∙Insert the oven into the cupboard.
∙Open the door to expose the fixing holes in the side trims.
∙Secure the oven by 4 countersunk screws (fasteners are not supplied ).
∙The hob should be installed in a ventilated cupboard fitted with a sturdy worktop.
∙Secure the hob using the fixing brackets provided.
Under-counter installation
Worktop | 900 |
32mm - 48mm thick | Datum |
6 |
| +3 |
| 100 _0 | |
Vent | Top filler piece |
|
gap |
| |
at |
|
|
front |
|
|
only |
|
|
| Aperture | 590 +3 |
| 590 H x 565 W x 570 D | 0 |
| Aperture | |
|
| |
|
| (210) |
|
| Floor |
| + 3 |
|
| 565 _ 0 Aperture |
|
Typical section showing |
ventilation requirements |
Hob installation
|
| ( 35 ) | ||
|
| 485 | +3 | |
|
| _0 | ||
Worktop front | 80 | +3 | ||
_ | 0 | |||
|
|
|
| |
560 | +3 |
|
|
|
_ |
|
|
| |
| 0 |
|
|
|
3