SECO-LARM USA SK-1323-SPQ, SK-2323-SDQ Programming Output #1, 1.1User Code Only, User Card Only

Models: SK-1323-SDQ SK-1323-SPQ SK-2323-SDQ SK-2323-SPQ

1 4
Download 4 pages 23.3 Kb
Page 3
Image 3
Programming Output #1

ENFORCER Outdoor Stand-Alone Keypad Quick Programming Guide

Programming Output #1

Each Output #1 user can be programmed to have a user code and a user card.*

1.1User Code Only

1.Enter Programming Mode by entering the Master Code twice.

2. Enter a user ID number. ( 0 1.1User Code Only1.2 User Card Only* 0 1.3 User Card and Code*Manual background 0 to 9 Manual backgroundManual background 9 Manual backgroundManual background 9 )

3.If the left LED is red, previous user data exists. Clear it by entering Manual backgroundManual background . The keypad will beep in confirmation and the left LED will turn green.

4.Enter a new 5-digit user code.

5.To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.

6.Exit Programming Mode by pressing Manual background .

1.2 User Card Only*

1. Enter Programming Mode by entering the Master Code twice.

2. Enter a user ID number. ( 0 Manual backgroundManual background 0 Manual backgroundManual background 0 to 9 Manual backgroundManual background 9 Manual backgroundManual background 9 )

3.If the left LED is red, previous user data exists. Clear it by entering Manual backgroundManual background . The keypad will beep in confirmation and the left LED will turn green.

4.Swipe a new user card.

5.Return to Programming Mode by pressing Manual background .

6.To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.

7.Exit Programming Mode by pressing Manual background again.

1.3 User Card and Code*

1. Enter Programming Mode by entering the Master Code twice.

2. Enter a user ID number. ( 0 Manual backgroundManual background 0 Manual backgroundManual background 0 to 9 Manual backgroundManual background 9 Manual backgroundManual background 9 )

3.If the left LED is red, previous user data exists. Clear it by entering Manual backgroundManual background . The keypad will beep in confirmation and the left LED will turn green.

4.Swipe a new user card.

5.Enter a new 5-digit user code.

6.To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.

7.Exit Programming Mode by pressing Manual background .

*SK-2323-SPQ and SK-1323-SPQ only.

SECO-LARM U.S.A., Inc

3

Page 3
Image 3
SECO-LARM USA SK-1323-SPQ, SK-2323-SDQ Programming Output #1, 1.1User Code Only, User Card Only, User Card and Code