SECO-LARM USA SK-2323-SDQ user manual Programming Output #2, 2.1Programming an Output #2 User Code

Models: SK-1323-SDQ SK-1323-SPQ SK-2323-SDQ SK-2323-SPQ

1 4
Download 4 pages 23.3 Kb
Page 4
Image 4
Programming Output #2

ENFORCER Outdoor Stand-Alone Keypads Quick Programming Guide

Programming Output #2

Each Output #2 user may only have a user code OR a user card programmed.

2.1Programming an Output #2 User Code

1.Enter Programming Mode by entering the Master Code twice.

2.Enter 2.1Programming an Output #2 User Code2.2Programming an Output #2 User Card*Manual background 4 .

3. Enter a user ID number. ( 0 Manual backgroundManual background 0 to 0 Manual backgroundManual background 9 )

4.If the left LED is red, previous user data exists. Clear it by entering Manual backgroundManual backgroundManual background . The keypad will beep in confirmation and the left LED will turn green.

5.Enter a new 5-digit user code.

6.To program the next user, repeat from step 3 in section 2.1 or 2.2.

7.Return to Programming Mode by pressing Manual background .

8.Exit Programming Mode by pressing Manual background again .

2.2Programming an Output #2 User Card*

1.Enter Programming Mode by entering the Master Code twice.

2.Enter Manual backgroundManual backgroundManual background 4 .

3. Enter a user ID number. ( 0 Manual backgroundManual background 0 to 0 Manual backgroundManual background 9 )

4.If the left LED is red, previous user data exists. Clear it by entering Manual backgroundManual backgroundManual background . The keypad will beep in confirmation and the left LED will turn green.

5.Swipe a new user card.

6.To program the next user, repeat from step 3 in section 2.1 or 2.2.

7.Return to Programming Mode by pressing Manual background .

8.Exit Programming Mode by pressing Manual background again.

*SK-2323-SPQ and SK-1323-SPQ only.

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2010 SECO-LARM U.S A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.

SECO-LARM®U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606

Website: www.seco-larm.com

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

E-mail: info@seco-larm.com

PICCN2

SK-x323-SxQ Addendum_1008.docx

4

SECO-LARM U.S.A., Inc.

Page 4
Image 4
SECO-LARM USA SK-2323-SDQ, SK-2323-SPQ, SK-1323-SDQ user manual Programming Output #2, 2.1Programming an Output #2 User Code