SECO-LARM USA ST-2406-3AQ Do Not Use Metal Spacers To Mount The Power Supply’S Pc Board

Models: ST Series ST-2406-7AQ ST-2406-5AQ ST-2406-2AQ ST-2406-10AQ ST-1206-1.5AQ ST-2406-3AQ

1 2
Download 2 pages 1012 b
Page 2
Image 2
3.DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY’S PC BOARD.

Figure 1 – ST-1206-1.5AQ wiring diagram

Figure 2 – ST-2406 Series wiring diagram

 

(black) To back-up battery negative (-) input

 

(red)

To back-up battery positive (+) input

 

 

 

 

Wire loop

1ACI/P 2

3DC O/P 4

 

Red Led

 

Green AC Input LED

indicator

 

 

To Class-II

To alarm or access control

 

 

transformer

panel VDC positive (+) input

AC

+DC

VAC outputs

To alarm or access control

 

 

 

To Class-II

 

 

panel VDC negative (-) input

 

 

 

transformer

 

 

 

VAC outputs

 

 

 

To alarm or access

 

 

 

control panel VDC

 

 

 

positive (+) input

 

4.Measure DC output before connecting devices. Red DC Output LED

-- BAT +

Transformer selection table: To back-up battery positive (+) input To program DC voltage output: To back-up battery negative (-) input

* For ST-1206-1.5AQ model. See point 2 under Installation. To alarm or access control panel VDC negative (-) input

3. Connect the wirings to their respective terminals (see Figure 1 and 2).

NOTE:

a.

Before connecting any external devices, temporarily power up the unit and measure the DC output voltage

 

 

to avoid damage to devices. Then disconnect power before connecting external devices.

 

b. LED status — for ST-1206-1.5AQ, Red LED on indicates connections to AC power.

 

 

for ST-2406 series, see Table 3.

WARNING:1. Using a higher AC input than recommended may damage the unit.

2.When a power supply/charger is used at its maximum load for an extended period of time, the heatsink portion of the power supply/charger will be very hot.

3.DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY’S PC BOARD.

4.Measure DC output before connecting devices.

Table 1:

Transformer selection table:

Output voltage

ST-1206-1.5AQ

ST-2406-2AQ

ST-2406-3AQ

ST-2406-5AQ

ST-2406-7AQ

ST-2406-10AQ

 

 

 

 

 

 

 

6VDC

12VAC/20VA

12VAC/20VA

ST-UV24-W50Q

ST-UV16-W100Q

ST-UVDA-W180Q

ST-UVDA-W180Q

24VAC/50VA

16VAC/100VA

24-28VAC/180VA

24-28VAC/180VA

 

 

 

 

 

 

 

 

 

 

12VDC

16VAC/40VA

16VAC/40VA

ST-UVDA-W100Q

ST-UV16-W100Q

ST-UVDA-W180Q

ST-UVDA-W180Q

24-28VAC/100VA

16VAC/100VA

24-28VAC/180VA

24-28VAC/180VA

 

 

 

 

 

 

 

 

 

 

24VDC

N/A

ST-UV24-W50Q

ST-UVDA-W100Q

ST-UVDA-W180Q

24-28VAC/210VA

ST-UV28-T350Q

24VAC/50VA

24-28VAC/100VA

24-28VAC/180VA

28VAC/350VA

 

 

 

 

 

 

 

 

 

 

Table 2:

To program DC voltage output:

Voltage

SW1

SW2

6V

ON

OFF

12V

OFF

OFF

24V

OFF

ON

* For ST-1206-1.5AQ model. See point 2 under Installation.

Table 3:

LED status for ST-2406 series:

Green LED

Red LED

Status

 

 

 

ON

ON

Normal

OFF

ON

No VAC input

 

 

 

ON

OFF

No VDC output

OFF

OFF

No VAC input and VDC output

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.

WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.

This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

SECO-LARM®U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606

Website: www.seco-larm.com

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

E-mail: sales@seco-larm.com

 

MuST12-2406Q_084.pmd Order Part #763-074-8%

PITSW1

Page 2
Image 2
SECO-LARM USA ST-2406-3AQ Do Not Use Metal Spacers To Mount The Power Supply’S Pc Board, Transformer selection table