Seiko 5d88 manual Display

Models: 5d88

1 12
Download 12 pages 48.71 Kb
Page 8
Image 8

English

will result.

The watch can be charged if it is swung from side to side, however, it may take time until it displays the power generation status.

Even if the watch is worn on the wrist after it is charged fully (power reserve of 30 days), and then it is left untouched, the watch will not operate for more than 30 days after it is worn again.

When you take off the watch and leave it untouched, look at the indicator to check if the watch continues to operate until you wear the watch the next time, and turn the crown to charge the watch as necessary (make sure to store extra power so as not to stop operation of the watch).

<Display and movement flow of the direct drive indicator hand while charging the watch>

Power

 

Power generation status and generated power display

 

reserve

Initial status

 

In-progress

 

 

display

After

A. While turning the

B. When temporarily

 

 

 

approximately

A

B

 

1 second

crown

stopping turning the

 

 

 

 

since starting

 

crown

 

 

 

to turn the

 

 

 

 

 

crown

 

 

 

 

The power reserve indicator hand

 

Power reserve

points at a scale marking between 0

 

 

and ”M+1” according to power gen-

 

After

display

eration status.

 

 

 

 

approximately

 

The point where the indicator

4 seconds

 

 

 

hand starts moving goes up as

since stopping

 

 

 

 

generated power increases.

turning the

 

 

crown

 

 

 