AN.No.G1216B1N000-3D0E

3.OPERATING INSTRUCTIONS

3.1Terminal Functions

Table 1 Terminal Functions

Signal

QTY

I/O

Destination

 

 

 

Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB0 to DB7

8

I/O

MPU

Common terminal for tristate input and output, and data bus.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

1

Input

MPU

Enable

 

 

 

 

 

 

 

 

 

 

 

 

Write (R/W=0):Latches data of DB0 to DB7 at the fall of E.

 

 

 

 

Read (R/W=1):Outputs data to DB0 to DB7 while “E” keeps a

 

 

 

 

high level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

1

Input

MPU

Read/Write selection

 

 

 

 

 

 

 

 

 

 

R/W=1: When E=1 and CS1=0 or CS2=0, the data is output

 

 

 

 

 

to DB0 to DB7 and read is available by MPU.

 

 

 

 

R/W=0: When CS1=0 or CS2=0, DB0 to DB7 are ready for

 

 

 

 

 

receiving the input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D/I

1

Input

MPU

Data/Instruction selection

 

 

 

 

 

 

 

 

 

 

D/I=1: Indicates that the data in DB0 to DB7 is the display

 

 

 

 

 

data.

 

 

 

 

 

 

 

 

 

 

 

 

D/I=0: Indicates that the data in DB0 to DB7 is the instruction

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1, CS2

2

Input

MPU

Chip select input. Data input and output is possible under

the following status:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCM display screen

 

 

 

 

 

Terminal No.

 

CS1

 

CS2

 

 

 

 

 

 

 

 

 

 

 

CS1

 

CS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1: Controls the LCM left half display screen (SEG1 to

 

 

 

 

SEG64).

 

 

 

 

 

 

 

 

 

 

 

 

CS2: Controls the LCM right half display screen (SEG65 to

 

 

 

 

SEG128).

 

 

 

 

 

 

 

 

RST

1

Input

MPU

Reset signal

 

 

 

 

 

 

 

 

 

 

 

 

Setting the RST signal to a low level allows for initial setup.

 

 

 

 

 

(1) ON /OFF register: 0 setup (display OFF)

 

 

 

 

 

 

 

 

(2) Display start line register: 0 line setup (display starts

 

 

 

 

 

from 0 line)

 

 

 

 

 

 

 

 

 

 

 

 

The setup status is retained until the status is changed by an

 

 

 

 

instruction after reset is released.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDD

1

 

Power

Power terminal for logic (+5 V)

 

 

 

 

 

VSS

1

 

Power

GND terminal (0 V)

 

 

 

 

 

 

VLC

1

 

Power

Power terminal for LC drive

 

 

 

 

 

 

LEDA

1

 

Power

LED backlight anode terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEDC

1

 

Power

LED backlight cathode terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FGND

1

￿

￿

Frame ground1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1FGND terminal is connected to the metallic frame of the module. Use this terminal when grounding the frame.

- 14 -