Switching the central unit on/off
After connection to the mains, the device switches on automatically and the ON button lights up.
Press the ON button
Note:
If the power supply is interrupted for several seconds (e.g. due to a power failure), the device switches on automatically even if it was switched off before.
Adjusting the sensitivity
|
| With the microphone connected and both the gain switch | and the level | |
|
| control set to 0 dB, the specified sensitivity (mV/Pa) is obtained. | ||
|
| Use the gain switch | to increase the output voltage level by 20 dB | |
0 20 40 | +/- 15dB | (tenfold increase) or 40 dB (hundredfold increase). |
| |
|
|
| ||
| 0 | Use the level control | to steplessly adjust the output voltage level | |
| OVERLOAD | |||
dB | LEVEL | between |
| |
GAIN |
|
|
|
0 20 40 | +/- 15dB |
| 0 |
| OVERLOAD |
dB | LEVEL |
GAIN |
Overload indication
The OVERLOAD LED indicates both positive and negative voltage peaks.
If the OVERLOAD LED | lights up: |
Use the gain control | and/or the level control to reduce the output |
voltage level so that the OVERLOAD LED no longer lights up.