Cleaning and maintaining the L 1039-10

Indications of the status LEDs

 

Status LED 3

Meaning

 

lights up red

receiver is being charged

 

flashes red

error, charging compartment is deactivated (see page 10)

 

2

 

 

Status LED 8

Meaning

 

lights up green

receiver is fully charged

8

3

 

Charging times

With a completely discharged accupack and at room temperature, the charging times are as follows:

Capacity obtained

Charging time

approx. 100%

typ. 3-4 hours

 

 

However, charging may take longer under the following circumstances:

The accupack is deep-discharged and first has to be reconditioned by a deep discharge recovery charge.

The ambient temperature is close to or over 45°C/113°F; in order to protect the accupack, the charging power will be reduced until the accupack temperature has dropped to an admissible value.

Charging will be aborted and the status LED 3will start flashing red under the following circumstances:

The accupack temperature is too low or too high (see “Specifications” on page 11); charging starts automatically when the accupack temperature is within the charging temperature range.

The accupack is defective.

Cleaning and maintaining the L 1039-10

CAUTION

Liquids can damage the electronics of the product!

Liquids entering the housing of the product can cause a short-circuit and damage the electronics.

￿Keep all liquids away from the product.

￿Do not use any solvents or cleansing agents.

￿Remove all bodypack receivers/transmitters from the charging compartments.

￿Before cleaning, disconnect the mains unit from the mains.

￿Use a soft, dry cloth for cleaning.

￿Use a brush or similar to remove dust from the charging compartments.

L 1039-10 9