If a problem occurs ...

If a problem occurs ...

Problem

Possible cause

Solution

The status LEDs

Charger is not connected

Check if the charger is connected

3 and 8 do

to the mains

to the NT 12-50C mains unit and

not light up

 

if the mains unit is connected to

 

 

the mains (see page 7).

 

Unstable voltage of the

Replace the defective mains unit

 

mains unit

or mains cable with a new one.

 

Mains unit or mains cable

 

 

is defective

 

 

No contact with the

Insert the bodypack receiver/

 

accupack

transmitter –with the accupack

 

 

installed – correctly into the

 

 

charging compartment

 

 

(see page 8).

 

Contacts of the receiver or

Clean the charging contacts of

 

contacts of the charging

the receiver and of the charging

 

compartment are dirty

compartment (see page 9).

 

Accupack is defective

Replace the defective accupack

 

(overaged or defective

with a new one.

 

rechargeable battery cells)

 

The status

Wrong accupack/indi-

Only charge BA 2015 accupacks

LED 3 flashes

vidual rechargeable

(installed in a bodypack receiver/

red

batteries/batteries

transmitter) with the L 1039-10

 

(primary cells) have

charger.

 

been inserted

 

 

Accupack temperature is

Always recharge the accupacks

 

too low or too high

within the operating temperature

 

 

range and the air humidity range

 

 

stated in the specifications

 

 

(see page 11).

 

Accupack is defective

Replace the defective accupack

 

(overaged or defective

with a new one.

 

rechargeable battery cells)

 

 

 

 

10 L 1039-10